Valid for: RMOD400-80-13SEW
Installation and Operating Instructions
DC/DC Converter: RMOD400-EW Series
Other applicable document:
Important Safety Information
Technical Data
At 24/80VDC, full load forced air cooling, 25°C, with 5 minute
warm-up time unless otherwise stated
nom. Output Power – continuous
Output Voltage (Factory Setting)
Output Current
Efficiency
Typical Input Voltages
Input Voltage Range – continuous
Extended Input Voltage Range
Input Current
Inrush Current (cold start)
Input Reverse Polarity Protection
Short Circuit Protection
Over Current Protection
Over Temperature Protection
Operating Temperature
IP protection class
Storage Conditions
Operating Humidity
Operating Altitude
Dimensions (L x W x H) / Weight
Approvals
Warranty
Fig. 1: Mounting Instructions / Montageanleitung
10.5 max.
Screw (M6)
Schraube (M6)
RMOD
Customer Application
Kundenanwendung
Fig. 2: Mechanical Dimension / Mechanische Dimensionen [mm]
53.0
53.0
53.0
Top View
Draufsicht
203.0
203.0
203.0
Front View
Ansicht von Vorne
FC 189.0
FC 189.0
FC 189.0
FC 6.0
FC 6.0
FC 6.0
Bottom View
Ansicht von unten
4x Ø6.5
4x Ø6.5
4x Ø6.5
Tolerance/Toleranz: ±0.5mm
©RECOM Power GmbH. The information contained in
this instructions and accompanying drawings are the
Technische Daten
Bei 24/80VDC, Volllast, Zwangsbelüftung, 25°C, nach 5 Minuten
Aufwärmzeit, wenn nicht anders angegeben
nom. Ausgangsleistung - dauerhaft
Ausgangsspannung (Werkseinstellung)
Ausgangsstrom
Wirkungsgrad
Typische Eingangsspannungen
Eingangsspannungsbereich - dauerhaft
Erweiterter Eingangsspannungsbereich
Eingangsstrom
Einschaltspitzenstrom (Kaltstart)
Eingangsverpolungsschutz
Kurzschlussschutz
Überstromschutz
Übertemperaturschutz
Betriebstemperatur
IP-Schutzklasse
Lagerbedingungen
Betriebsluftfeuchtigkeit
Betriebshöhe
Abmessungen (L x B x H) / Gewicht
Zulassungen
Garantie
Recommended Mounting Screw:
Use M6 screws of minimum length 12mm and with a head
diameter of 10.5mm maximum.
Stainless steel screw - recommended maximum torque 4.6
Nm (40.7 in-lb). Correct torque should be established for each
use case.
Empfohlene Montage Schraube/Unterlegscheibe:
Verwenden Sie M6-Schrauben mit einer Mindestlänge von 12
mm und einem Kopfdurchmesser von maximal 10.5 mm.
Schrauben aus rostfreiem Stahl - empfohlenes maximales
Drehmoment 4.6 Nm (40.7 in-lb). Das richtige Drehmoment sollte
für jeden Anwendungsfall ermittelt werden.
150.0
150.0
150.0
CON1
Connector
DC Input CON1
DC Output CON2
FC= fixing centers
Connector
DC Input CON1
DC Output CON2
FC 138.0
FC 138.0
FC 138.0
DC Input CON1
DC Output CON2
FC= Montagelöcher
Anschluss
DC Input CON1
DC Output CON2
Revision: 0/2023
Document no.: IMG111
intellectual property of RECOM Power GmbH.
This manual can change without prior notice.
13VDC at 33.6-120VDC Input / 13VDC bei einer Eingangsspannung von 33.6-120VDC
12VDC at 24-33.6VDC Input / 12VDC bei einer Eingangsspannung von 24-33.6VDC
current limitation, auto recovery / Strombegrenzung, Automatischer Neustart
40.5A typ., current limitation, auto recovery / 40.5A typ., Strombegrenzung, Automatischer Neustart
(never exceed max. allowed base plate temperature= +70°C) / Maximal zulässige Grundplattentemperatur von +70°C darf nicht überschritten werden
-40°C...+85°C, 95% RH max. Non-condensing / nicht kondensierend
UL62368-1:2014, CAN/CSA-C22.2 No. 62368-1-14, IEC/EN62368-1:2014
Fig. 3: Input Voltage Range / Eingangsspannungsbereich
100
53.0
Fig. 4: Derating Graph / Temperaturverhalten
AC Input Side View
AC Eingangsseite
CON2
2
1
4
3
Connector Information
#
Function
1
+V
IN
2
-V
IN
3
-V
OUT
4
+V
OUT
Thermal Consideration: / Thermische Betrachtung:
Compatible Connector
Housing
FEP 1K0 971 955
FEP 3B0 973 752 A
Anschluss Information
required cooling surface (heat sink)/erforderliche Kühlfläche (Kühlkörper)
Stecker
#
Funktion
1
+V
IN
2
-V
IN
3
-V
OUT
4
+V
OUT
The module can be used in enclosed applications, as long as the cooling is sufficient to keep the
Kompatibler Stecker
baseplate temperature below 70°C. The surrounding temperature should not exceed 85°C.
Gehäuse
Das Modul kann in geschlossenen Applikationen eingesetzt werden, solange die Kühlung
FEP 1K0 971 955
ausreicht, um die Temperatur der Grundplatte unter 70°C zu halten. Die Umgebungstemperatur
FEP 3B0 973 752 A
sollte 85°C nicht überschreiten.
*
techsupportemea@recom-power.com
RMOD400-80-13SEW
400W
30.8A
80%
48/80/96VDC
33.6-120VDC refer to Fig. 2 / Siehe Abb. 2
24.0-33.6 for 5 minutes max. refer to Fig. 2 / Siehe Abb. 2
22A
1.5A²/s
-120VDC
yes / ja
-35°C to +85°C
IP69K
95% RH max.
3000m
203.0 x 115.0 x 61.0mm / 1.7kg
2 years / 2 Jahre
150.0
continuous operation
5min
Dauerbetrieb
0
24.0
33.6
120
Input Voltage [VDC]
Eingangsspannung [VDC]
35
203.0
30.8
30
25
20
15
12
10
5
FC 189.0
FC 6.0
FC 138.0
0
-35
-20
-10
0
10
20
Ambient Temperature [°C]
Umgebungstemperatur [°C]
RMOD400-EW
4x Ø6.5
T
case
T
natural convection 0.1m/s
natürliche Konvektion 0.1m/s
RECOM Power GmbH
Münzfeld 35, 4810 Gmunden, AUSTRIA
+43 7612 88325 700
+43 7612 88325 801
7
www.recom-power.com
Recognized by safety agency for safe
operation at input voltage up to 108VDC
Anerkannt von der Sicherheitsbehörde
für sicheren Betrieb bei einer Eingangs-
spannung von bis zu 108VDC
30
40
50
60
70
80
90
85
Wäremeleitpad
heat pad
/T
Gehäuse
/T
amb
Umgebung