Quick guide extraction systems STW164IP
1 Application and short description
Controllers STW164IP allow in conjunction with slider controls STW168M and bus modules.
STW161M controls extraction systems with up to 32 machines.
The STW164IP control serves as the central control unit. It records the operating state of the machines by measuring their
current consumption in the supply lines (current transformer STWA1 (H)) or via potential-free contacts.
It switches on the central extraction and opens the sliders on the channels to the individual machines.
2 Technical data
Control voltage Us:
Tolerance
Power consumption
duty cycle
Inputs I0 ... I31:
Connectable transducers
AC internal resistance Overload
capacity
With STWA1 (H) switch-on value
Switch-on value
Tolerance
RS485 BUS for
STW161M/STW168M:
Cable
Length
When selecting and dimensioning the cable, it must be ensured that sufficient voltage is
available on each BUS participant (STW164IP, STW161M/STW168M with slider/flaps).
Power consumption of the BUS devices for the calculation:
• STW164IP
• Connected STW161M
• Connected STW168M
• Connected sliders / flaps
4 Display and controls
4
1
2
STW164IP
12660-0751-00
Mains Monitoring
Digital Panelmeters MINIPAN®
• Control of up to 32 sliders via bus line in connection with bus modules STW168M
and STW161M
DC 24 V
DC 20 – 30 V
< 3W
100 %
- STWA1(H) (terminals I- and I0...I15)
- Potential-free contact (terminals Y+ and I0...I15)
- Ziehl current sensor S1 (S1 output PNP at
I0...I15, Us of S1 at Y+ and I-)
approx. 15kΩ
max. 100A continuous, max. 300A for 10s
adjustable 0.5...9.9 A with current
transformerSTWA1 (H)
±20 % (current transformer STWA1(H))
recommended: twisted, shielded (twisted pair)
max. 1000 m (RS485 BUS)
approx. 3 W
approx. 0,5 W
approx. 3,5 W
approx. ... each on the customer's
1.
Display - Colour display
3
2.
Control element - Joystick button
3.
LED - Ethernet connectivity
4.
RS485 BUS terminating resistor.
⇒ Both DIP switches on = terminating resistor on
Switching Relays and Controls
You can get further information and help via the
search for
STW164IP
Datasheets, Operating Manuals and quick guides, Connection
Plans, CAD-Data, copious FAQ, Certificates.
3 Connection Plan
RS485 BUS: Switch on terminating resistors at the beginning
and end of the BUS line
• STW164IP:
• STW161M:
• STW168M:
If the STW164IP is not located at the beginning or end of the
BUS line, the terminating resistors must be switched on at
the corresponding STW168M or STW161M (beginning and
end of the BUS line).
Seite 3 / 4
ZIEHL industrie – elektronik GmbH + Co KG
Daimlerstr.13, 74523 Schwäbisch Hall, Germany
+ 49 791 504-0,
info@ziehl.de,
Measuring Transducers
Grid- and Plant Protection
updated: 2023-12-05 / dr
at ziehl.de.
2 x DIP switch "RS485 terminate" to on,
DIP switch "Terminate" to on
Both DIP switches "RS485 terminate" to on
www.ziehl.deAA
www.ziehl.de
QR-Code
or

Werbung

loading