Safety instructions
The appropriate local installation specifications, directives and regulations must be followed. This applies
especially to the VDE directives and regulations, e.g., DIN VDE 0100 and IEC 60364.
No liability is assumed for damage arising from improper use, assembly and installation, and from use of
non-original parts and accessories!
For safety and product approval (CE) reasons, the product must not be converted or modified.
Before starting any installation, repair, maintenance or adjustment work, ensure that no voltage is applied to
any of the power supply units and protect against unintended switch-on.
Claims made under the warranty for damage caused by non-observance of these instructions will become
invalid! No liability is assumed for consequential damages!
Please hand this document over to the user!
Technical data
General description
With the ixalo release terminal Pro (FGT Pro) you can exchange programming data, daytime
releases and events between the BKS KeyManager software and the RFID transponders.
Environmental
conditions
Operating voltage
12 ... 24 V DC (–15%/+10%)
Recommended power
supply units
Current consumption
80 mA
Max. length of RS485 bus 1,000 m
Relay output
Contact load 0.5 A at 30 V DC
Data transmission
* MIFARE DESFire and MIFARE Classic are registered trademarks of NXP B. V
Transponder
Master card
Dimensions
44 x 75 x 29 mm
Certification
Installation
The place of installation must allow sufficient distance between the reader and possible
sources of interference (power supply units, RFID readers, etc.). In order to obtain sufficient
space for the connecting cable, we recommend the use of flush boxes (61 mm depth).
Recommended type of cable: J-Y(ST)Y 4x2x0.8 mm.
The aerial connector must be inserted into the socket provided, see underneath.
optional
+55°C
IP20
°C
–20 °C
B 5494 0013 (ready for plug-in)
B 5570 0403 oder B 5570 0404 (DIN rail mounting)
MIFARE® DESFire®* (min. 2 kB of free memory on transponder required)
®*
MIFARE Classic
(1 kB and 4 kB transponder)
Data is encrypted with AES-128
RFID transponders 5931 |5932 | 5934 | 5935 | 5937 | 5938
System master card 5930 for RFID technology
The certificates can be found at our website www.g-u.com.
with B 5858 0005 sealing collar
IP44
.