Herunterladen Diese Seite drucken

IFM Electronic efector500 PL2652 Bedienungsanleitung Seite 13

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Function and features
The pressure sensor detects the system pressure and converts it into
an analog output signal (4 ... 20 mA). The measuring range can be
scaled to up to 25% of the value of the span (→ page 18).
It is also indicated:
• System pressure above the measuring range: output signal > 20mA.
• System pressure below the measuring range: output signal drops to
max. 3.2 mA (depending on the scaling).
Applications
Type of pressure: relative pressure
Measuring range
bar
MPa
-0.1 ... 10
PSI
Avoid static and dynamic overpressure exceeding the given over-
load pressure.
For gaseous media the application is limited to max. 25 bar.
Even if the bursting pressure is exceeded only for a short time
the unit can be destroyed (danger of injuries)!
The unit is ready for operation when delivered.
Factory preset: not scaled (ASP = 0 bar; AEP = 100 bar).
-1 ... 100
-10 ... 1 450
Permissible
overl. pressure
200
20
2 900
1
Bursting
pressure
650
65
9 425
13

Werbung

loading