Herunterladen Diese Seite drucken

JBM 50917 Bedienungsanleitung Seite 3

Ölpumpenzange mit digitalem durchflussmesser

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
REF. 50917
EN
INSTRUCTION MANUAL
PRESENTATION
Measures the quantity of dispensing engine oil, Gear
Oil, ATF Oil, anti-freeze and allied products, with the
construction of aluminium body swivel and in-built ba-
lanced valve.
PARTS LIST
1
Connector
2
Nozzle body
3
Handle
4
Valve seat
5
Valve stem
6
Spring
OPERATION
Connector (1) has to be connected to pressurized oil
through the gun body with a hose and a pump. Open
the valve stem (5) with the handle (3), the oil enters
the nozzle pipe (10) through the valve seat (4), open
the check valve in the nozzle (9) and the oil flows out
from the gun.
INSTRUCTIONS
TECHNICAL SPECIFICATIONS
The flow meter screen is digital liquid crystal display, 5
digits of single refuelling amount.
4 Types of optional unit: L, GAL, Qtrs., Pts;
2 Operation keys:
Keys:
1. The single fuel quantity data is cleared: press
key.
2. Switch between total accumulation and category
accumulation: press
the word "TOTAL" on the screen is the total accu-
mulation, the data in front of "
accumulation.
3. Class cumulative removal: Hold down the
7
Oil seal
8
Connector
9
Spout
10
Nozzle pipe
11
Protector
;
.
, key, the data in front of
" is the category
button for three seconds, showing "CLEAN" word,
press
key to make sure to delete accumulated
data; press
lated data.
4. Adjustment factor: Hold down the
seconds, enter adjustment mode: Press the
button to select the number of digits to change,
press the
key to change the number until the
desired number is displayed, Exit automatically
after three seconds. Coefficient* range is 0-9999,
the standard 1050-1100, don't adjust without rea-
son. When there's an adjustment, the oil error per-
centage is about + 0.8‰, and the more increased
the coefficient, the more oil will be displayed on
the screen, and vice versa.
*Coefficient is the relationship between the flow and
the calculation. For example, if you replenish 20l of oil,
the meter shows 20l, then the coefficient is 1. If you
replenish 20l of oil, but the meter shows 30l, then it is
necessary to adjust the coefficient to make it smaller.
5. Change the unit of measurement: Hold down
the
key for three seconds, enter adjustment
mode, press the
measurement to be changed, press the
to change the unit until the desired unit is displa-
yed, and automatically exit after three seconds.
REPLACEMENT OF BATTERIES
Oil flow meter 2. 1.5 V battery 3. Battery cover
When the batteries are low, the symbol
appear on the display. Replace the batteries on time,
in order to do it you need 2 new alkaline environmental
protection No. 8 LR1-N batteries.
TECHNICAL SPECIFICATIONS
Air inlet . . . . . . . . . . . . . . .1/2" BSPF
Flow rate . . . . . . . . . . . . . 1-35 L/min
Working Pressure
Max. working pressure . . . . . . . . . . 100bar
Oil temperature range . . . . . . . . -10ºC~60ºC
Maximum viscosity . . . . . . . . . . 240 SAE
Battery . . . . . . . . .2×1.5V (battery included)
Weight
. . . . . . . . . . . . . . . 1.4 kg
Flow meter accuracy
Flow meter repeatability . . . . . . . . .
Discharge Rate per Revolution
· 3 ·
key to cancel deleting accumu-
key for three
button to select the unit of
. . . . . . . . . . . 6-8 bar
. . . . . . . . .
. . . . . . 25ml/R
button
will
±0,5%.
0,2%