CV
Table EVO-S
Standard settings (D
=
Factory
Default,
PoM
=
Programmable with SPoM)
Table of configuration variables (CV labte)
CV Descrlpllon
D PoM
Range
Note
7 Software version
read only
8 Manufacturer ID
123
read only
8 Decoder reset functions (see attachment 1)
8
All CVs (without CV 15+ 16)
4 reset ranges available
11
basic settings
(Reset values on page 37)
16
Programming lock
22
Function Settings
11 DCC Timeout
10
1...200 1 OOms per value
15 Programming lock (Key)
101
0
...
255 When CV15
=
CV16,
then the
16 Programming lock (Lock)
101
1...199 decoder is programmable
29 DCC Conliguration
132
bitwise programming
Bit
Value
OFF {Value 0)
ON (add all active values)
Bit2
4
digital operation only
digital + analog operation
Bit 7
128
loco address mode (deactivated)
switch address mode
41 Switch address (High Byte)
0
1...
42 Switch address (Lew
Byte)
1
2046
50 Operation Mode
0
bilwise programmlng
B11
Value
OFF {Value 0)
ON {add all acllve values)
811
0
1
freewheel function active
freewheel function not active
Bit 6
64
softstart function
no softstart function
Bit 7
128
standard switching direction
oposite switching direction
51 nme automatic reverse right
0
0
...
255
52 nme automatic reverse left
0
0
...
255
o
=
oll, 1
...
255 time base 1 sec
53 Switch time delay free wheel right
0
0
...
255
(V.
2.2)
54 Switch time delay free wheel left
0
0 ... 255
112 Speed of Motion
100
50,
100 Value in % (V. 2.3)
119 shut oll current
5
1
...
10
ca.
10 ... 100mA
255 Decoder type EVO-S
244