D. DRYING YOUR ROOM
→ Press MODE button on the control panel or remote control. The dry indicator lights
up. Fan speed can not be selected. User should connect hose with drain outlet at the
bottom of the unit
Note: In this mode, the fan speed switches over to low speed and cannot be modified.
E. SLEEP MODE
The sleep mode can be activated when in cool mode.
→ In cool mode :
After 1 hour, the preset temperature is increased by 1 °C, followed by another one-degree-
decrease after another hour.
→ In heat mode (Optional for Heating Function Unit only):
After 1 hour, the preset temperature is increased by 1 °C, followed by another one-degree-
decrease after another hour.
Temperature is now constant for 10 hours. Indicators dim to dark. The fan speed may switch
over to low speed for silent operating and cannot be modified.
5.3.3 TIMER SETTING (1hour-24hours):
The timer has two ways of operation:
To turn off
(When power on)
To turn on
(When power off)
Press Up /Down repeatedly until the LED shows '00'.
Cancel timer
Note: When POWER ist pressed: Exit of timer setting.
5.3.4 AUTOMATIC DEFROST
At low room temperatures, ice may develop at the evaporator during operation. The
portable air conditioner will automatically start defrosting and the POWER LED blinks. The
defrost control sequence is as follows:
A. In case the unit works in position drying and cooling and an evaporator coil temperature
is measured below -1°C, compressor stops operation for 10 minutes. If ccoil temperature
reaches +7°C, unit returns to cool operation mode.
B. In case the unit works in position drying and coil temperature sensor recognises an
evaporator temperature below 40°C in connection with a temperature difference between
evaporator coil and room after 20 minutes evaporator operation of 19°C: Defrosting starts
for 5 minutes. Power LED is blinking. .
5.3.5 OVERLOAD PROTECTION
In the event of a power loss, to protect the compressor there is a 3-minute delay until the
compressor restarting.
Press Timer key to turn
on the timer function.
Press Timer key to turn
on the timer function.
Press Up /Down repeatedly
to set the delay OFF time.
Press Up /Down repeatedly
to set the delay ON time.