Herunterladen Diese Seite drucken

DAYLIGHT D21098 Anweisungen Seite 11

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
ENGLISH (USA)
Thank you for purchasing this Daylight product. To register your
purchase and read more information about your guarantee,
please go to www.daylightcompany.com
To ensure correct and safe operation please read the following
and retain for future reference
GENERAL INFORMATION
The Ultimate Floorstanding Lamp provides light, magnification,
chart/pattern holding facility and a storage tray. The accessories may
be removed when not required converting the lamp into an attractive
sitting room lamp. It is supplied in self assembly form – Please follow
the instructions below for quick and easy assembly.
SETTING UP YOUR LAMP
• Carefully unpack the lamp. You should have the following parts:
Weighted Base.
Base Pole.
C1
Main Assembly
An electrical cable fitted with a foot switch and plug
C1
passes through
Lamp Shade.
Shade Securing Ring.
20w ES(E26) Energy Saving Bulb
Flexible Arm with 1.75X magnification lens.
Flexible Arm with chart/pattern holder clip.
Storage Tray with transparent lid.
• Assemble the lamp as follows:
- Screw the Base Pole
taking care not to cross the threads. Ensure that the pole is
tight.
- Screw the short pole
- Screw the Main Assembly (
Base Pole
. Ensure the assembly is screwed tight. Also
take care not to tangle the cable. If it does get tangled
make sure it is untangled before the lamp is used.
- Unscrew the Shade Securing Ring
at the end of the curved pole
into position. Replace and tighten the Shade Securing
Ring
.
- Screw in the 20w Energy Saving Bulb
BY THE PLASTIC BASE NOT THE GLASS PART. DO NOT
OVERTIGHTEN.
- If required, insert the flexible arms with lens
attachments into the holes on the Accessory Supports
either side Lower Mount
- If required, fit the Tray
The tray should be offered up to the pole at 45°, hooked
on to the pole, rotated to a horizontal position and locked
in place with the latch. It should be fitted to the Fixed Pole
L
at any height between the Lower Mount
K
Upper Mount
.
- Your lamp is now ready for use.
OPERATION
Plug the lamp into a convenient electrical socket and switch on using
the footswitch. The height may be adjusted by pressing in the button
M
and moving the pole up or down as required.
REMOVING ACCESSORY SUPPORTS
To enhance the look of the lamp the Accessory Supports
hold the magnifier and clip may be removed. Pull the flexible arms
&
out of the supports. Pull the End Caps
unscrew and remove them. Re-fit the End Caps
with a detached short pole
C2
and
.
on to the thread on the Base
C2
on to the Main Assembly
C1
C2
&
) on to the
from the lampholder
and place the shade
GRIP THE BULB
and clip
.
Fig. 2
to the pole as shown in
and the
N
off the supports then
M
to the Lower
Mount
. Re-assemble in the reverse order.
CLEANING
CAUTION: BEFORE CLEANING UNPLUG THE LAMP FROM THE
ELECTRICAL SUPPLY.
• If the lamp requires cleaning simply dust it to keep it clean.
• If the shade becomes dirty remove the bulb and the shade. Clean the
shade with a soft cloth or in warm soapy water. Thoroughly dry the
shade before re-fitting.
• Take particular care when cleaning the high quality acrylic lens. To
avoid scratches use only a soft cloth dampened with warm soapy
water. NEVER USE AN ABRASIVE CLEANER. Take care not to touch
the lens with sharp objects.
• The tray may be cleaned with a soft cloth or in warm soapy water.
Thoroughly dry before re-fitting to the lamp.
• Do not use metal polish or spray cleaners on your lamp as they will
damage the surface.
REPLACING THE DAYLIGHT BULB
• Always switch off and remove the plug from the mains supply and
allow the lamp to cool before changing the bulb. NEVER touch the
C2
.
bulb while the lamp is switched on.
• The lamp is supplied with a 20w watt (equivalent to a 100w Tungsten
Bulb), E26 screw fitting Low Heat Daylight Simulation Bulb. (This type of
bulb is more suitable for detailed work rather than a hot tungsten bulb)
THE MAXIMUM WATTAGE BULB THE LAMP CAN ACCEPT IS A 60W
TUNGSTEN BULB - DO NOT USE BULBS OF A HIGHER WATTAGE,
THIS WILL DAMAGE YOUR LAMP AND INVALIDATE YOUR
GUARANTEE.
Replacement Daylight Simulation Bulbs can be obtained
direct from your local stockist. Code No: U15200.
• Simply unscrew the old bulb and screw in the new bulb. GRIP
THE BULB BY THE PLASTIC BASE NOT THE GLASS PART.
DO NOT OVERTIGHTEN.
• The old bulb should be re-cycled where local facilities are
available.
C1
SAFETY
WARNING: DO NOT LEAVE THE LENS UNATTENDED IN DIRECT
SUNLIGHT AS THIS CONSTITUTES A FIRE HAZARD. ALWAYS
REMOVE THE LENS FLEXIBLE ARM WHEN NOT IN USE.
CAUTION: Never touch the bulb when the lamp is switched on, or
position it so it may come into contact with curtains or drapes.
CAUTION: Take care not to raise the pole too high. The lower pole
C2
should not come out of the Lower Mount
become unstable if this occurs.
THE MAXIMUM WATTAGE BULB WHICH CAN BE USED IN THE LAMP
IS A 60W TYPE - A BULB OR SMALLER - DO NOT USE BULBS OF A
HIGHER WATTAGE , THIS WILL DAMAGE YOUR LAMP AND
INVALIDATE YOUR WARRANTY
P
CAUTION: The shade fitted to this lamp is specially designed to suit its
maximum wattage, changing the shade could affect your lamp's
.
electrical safety.
CAUTION: Take care not get the flexible cord tangled around the
weighted base or pole during assembly and during use.
CAUTION: This portable lamp has a polarized plug (ONE BLADE IS
WIDER THAN THE OTHER) as a feature to reduce the risk of electric
shock. This plug will fit in a polarized outlet only one way. If the plug
does not fit fully in the outlet, reverse the plug and try the other way. If it
still does not fit contact a qualified electrician.
NEVER USE WITH AN EXTENSION CORD UNLESS THE PLUG CAN BE
FULLY INSERTED.
DO NOT TAMPER OR ALTER THE PLUG.
DO NOT ATTEMPT TO USE THE LAMP ON A DIMMING CIRCUIT
P
used to
IN CASE OF DOUBT CONSULT A QUALIFIED ELECTRICIAN
as the lamp may

Werbung

loading

Diese Anleitung auch für:

E21098U21098A21098