Legend: Connecting the stove to a masonry flue
via the rear connection opening (figure 11)
1. Remove the removable bars (Legend 150:
3 pcs, Legend 240: 2 pcs).
2. Attach the flue connection pipe to the rear
connection opening. Ensure that the pipe fits
tightly in place.
3. Push the stove into place. Do not block the flue
by pushing the flue connection pipe too far into
the flue. If necessary, shorten the pipe.
4. Seal the flue connection pipe to the opening
in the fireproof wall, for example, by using
fireproof mineral wool. Make sure that the flue
connection is tightly sealed. Add more fireproof
mineral wool if necessary.
Figure 11.
Connecting the stove to a masonry flue via the rear connection opening (all dimensions in millimeters)
Abbildung 11. Anschluss des Ofens an einen gemauerten Rauchfang über die hintere Anschlussöffnung (alle
Abmessungen in Millimetern)
16
2
1
DE
Legend: Anschluss des Ofens an einen gemauerten
Rauchfang über die hintere Anschlussöffnung (Ab-
bildung 11)
1. Entfernen Sie die abnehmbaren Stangen (Le-
gend 150: 3 St., Legend 240: 2 St.).
2. Bringen Sie das Abzugsanschlussrohr an die hin-
tere Anschlussöffnung an. Das Rohr muss fest
an seinem Platz sitzen.
3. Schieben Sie den Ofen an seine Position.
Schieben Sie das Abzugsanschlussrohr nicht zu
weit in den Rauchfang hinein. Kürzen Sie das
Rohr, falls notwendig.
4. Dichten Sie das Abzugsanschlussrohr in der
Öffnung der feuerfesten Wand ab, z.B. mit feu-
erfestem Mineralwolle. Der Abzugsanschluss
muss absolut dicht sein. Fügen Sie gegebenen-
falls mehr Mineralwolle hinzu.