OBID i-scan
Table 11: Required external series resistor R
Notes:
•
The input is configured for a maximum input voltage of 5-10 V DC and an input current
of max. 20 mA.
•
Polarity reversal or overload on the input will destroy it.
FEIG ELECTRONIC GmbH
All manuals and user guides at all-guides.com
Installation
External voltage U
ext
5 V ... 10 V
11 V ... 15 V
16 V ... 20 V
21 V ... 24 V
Page 41 of 52
Required external series
resistor R
ext
---
270 Ω
560 Ω
820 Ω
ext
ID ISC.LRU3000
LRU3000 - Manual.doc