3.
Secure this side with proper taper stopple/pipe, and connect it with smoke output tube.
4.
Connect detector with DC12V battery: red with positive, black with negative. Do not connect
in a contrary way.
5.
Turn on the power switch, and the detector starts to work.
6.
In about 3 minutes, the pipe will be filled with smoke. Check the leak points. Please use head
lamp if necessary.
7.
After leak detection, please connect well the wires and pipe.
Notes:
* Please do leak detection away from smoke-sensitive parts.
* Do not run the detector over 8 minutes. It needs interval rest.
* The detector has protector. If it exceeds working limit, it will power off automatically. In this
condition, please operate it later.
* The round part of this detector is with temperature, be careful to avoid scalding injury.
5. MAINTENANCE
With longtime high temperature, the smoke and oil will oxidize and deteriorate. It will infect the ser-
vice life of smoke generated part, so please change smoke and oil regularly.
1.
Before filling fresh oil, please pour out the remaining oil in the detector.
2.
When the smoke output has water drops, please replace with fresh oil.
3.
Liquid paraffin and baby oil are OK.
Please fill fresh oil with equipped oil bottle.
6. HOW TO DO LEAKAGE TEST?
1.
Turn on device then block smoke exhaust port, record pressure gauge value.
2.
Connect smoke exhaust port to the pipe system you want to test.
3.
Wait for a while. Pressure gauge value decrease means the pipe system have leakage; pres-
sure gauge value show "0" means diameter of leakage point is more than 0.3mm.
7. PACKING LIST
1.
Main Unit.
2.
Hook (with hand-tighten nuts).
3.
Rubber stopples (with serial specification).
4.
Taper stopple.
5.
Taper pipe.
6.
30ml oil bottle.
7.
User manual.
8.
EVAP testing accessory.
9.
Adjustable inflate stopple.
8. PRODUCT INFORMATION
Power: DC12V, vehicle battery.
Smoke output value: 61/min.
Built-in air supply.