1 Intended use
For opening and closing small valves in underfl oor water heating systems. The actuator is
equipped with a visual position indicator to show the open or closed position of the valve .
Sygonix actuator can be connected to the mentioned valve types in conjunct ion with room
temperature controllers. With visible position indicator showing opening or closing of valve. If
you use the product for purposes other than those described, the product may be damaged.
Improper use can result in short circuits, fi res, electric shocks or other hazards.
The product complies with the statutory national and European requirements. For safety and
approval purposes, you must not rebuild and/or modify the product.
2 Delivery content
Electric actuator

3 Latest product information
Download the latest product information at
shown. Follow the instructions on the website.
4 Description of symbols
The following symbols are on the product/appliance or are used in the text:
Note: Remove if not shown in document
The symbol warns of hazards that can lead to personal injury.
The symbol warns of dangerous voltage that can lead to personal injury by electric
shock.
5 Safety instructions
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information on
proper handling in this manual, we assume no liability for any resulting per-
sonal injury or damage to property. Such cases will invalidate the warranty/
guarantee.
5.1 General information
The device is not a toy. Keep it out of the reach of children and pets.

Do not leave packaging material lying around carelessly. This may become dangerous

playing material for children.
If you have questions which remain unanswered by these operating instructions, contact

our technical support service or other technical personnel.
Maintenance, modifi cations and repairs must only be completed by a technician or an au-

thorised repair centre.
5.2 Handling
Please handle the product carefully. Jolts, impacts or a fall even from a low height can

damage the product.
5.3 Operating environment
Do not place the product under any mechanical stress.

Protect the appliance from extreme temperatures, strong jolts, fl ammable gases, steam

and solvents.
Protect the product from high humidity and moisture.

Protect the product from direct sunlight.

Do not switch the product on after it has been taken from a cold to a warm environment.

The condensation that forms might destroy the product. Allow the product to reach room
temperature before you use it.
Never operate the product in direct proximity of strong magnetic or electromagnetic fi elds

or transmitter aerials or HF generators. Doing so can prevent the product from functioning
properly.
5.4 Operation
Consult an expert when in doubt about the operation, safety or connection of the appliance.

If it is no longer possible to operate the product safely, take it out of operation and protect

it from any accidental use. DO NOT attempt to repair the product yourself. Safe operation
can no longer be guaranteed if the product:
– is visibly damaged,
– is no longer working properly,
– has been stored for extended periods in poor ambient conditions or
– has been subjected to any serious transport-related stresses.
Operating instructions

www.conrad.com/downloads
or scan the QR code
5.5 Mains cable
Do not modify or repair mains supply components including mains plugs, mains
cables, and power supplies. Do not use damaged components. Risk of death by
electric shock!
Make sure that the mains cable is not squeezed, bent, damaged by sharp edges or put

under mechanical stress.
Avoid excessive thermal stress on the mains cable from extreme heat or cold.

Do not modify the mains cable. Otherwise the mains cable may be damaged.

A damaged mains cable can cause a deadly electric shock.

Do not touch the mains cable if it is damaged.

– First, power down the respective mains socket (e.g. via the respective circuit breaker)
and then carefully pull the mains plug from the mains socket.
– Never use the product if the mains cable is damaged.
A damaged mains cable may only be replaced by the manufacturer, a workshop commis-

sioned by the manufacturer or a similarly qualifi ed person, so as to prevent any danger.
Ensure that cables are not pinched, kinked or damaged by sharp edges.

Always lay cables so that nobody can trip over or become entangled in them. This poses

a risk of injury.
6 Connected devices
Also observe the safety and operating instructions of any other devices which are con-

nected to the product.
7 Product overview
H30 Instructions
Overview and Features
★Used for controlling normally closed switch of small valves or PDM executive control
★On-off and stable control of closed loop valve
★Mounted on the pipeline of the water collector loop and the thermostatic valve
★The valve is closed when the electric actuator has a power failure
★The paraffin propeller is driven by heating PTC
★Spring-return function, the valve closed with power failure
★No noise during the running
Used for controlling normally closed switch of small valves and compatible with Power

★Indicate the stroke location and the opening
Distribution Modules (PDM) the control electrical diagram must be followed.
★Simple and fast installation of the nuts connecting, easy to disassemble
On-off and stable control of closed loop
(1) Technical Specifications

The valve is closed when the electric actuator has a power failure.

★Type: Normally close
No noise during operation.
★Supply Voltage: 230VAC ,110VAC ,24VAC

★Initial Current: 50mA
★Working Current: 6.5mA
8 Installation
★Power: 1.5W
Actuator assembly onto the valve is completed by an M30 threaded ring nut. No tools are to
★IP Grade: IP54

be used as excessive tightening could cause damage to the valve assembly.
★Stroke: 3.0mm
★Maximum Load: 110N
The threaded ring nut allows for comfortable cable positioning at any 360 angle on the

★Working Temperature:0℃-50℃
valve. The actuator should always be fi tted in a horizontal or vertical position, never upside
★Storage Temperature: 0℃-50℃
down. In chilled water circuits, positions which allow condensation to get into the actuator
★Security Level: II(double insulation)
are not advis able.
★Cable Length: 100cm
★Frist open time :180S ,close time 5-8mins according to the working temperature
For the correct functioning of the actuator, the electrical circuit should be sized based on

★Dimension: 62mm*30mm*39mm
the starting current.
(2) Installation
The electrical connection should be done by an electrician, based on the electric schemat-

ics of the Power Distribution Module (PDM)
Note:
After installation the red card must be pulled out so that the actuator can work properly!