FM2
Betriebsanleitung Mikrowellen Schalter
Operating Instructions microwave switch
SAFETY NOTES
If the device is used incorrectly, application related dangers may arise.
The transmitter must be installed, connected, commissioned, operated
and maintained by qualified and authorised personnel only and un-
der strict observance of these operating instructions, relevant national
standards, legal requirements, and where appropriate, the product cer-
tification.
INSTALLATION
For unrestricted functionality, there must be a good electrically con-
ductive connection between the sensor and the container housing.
We therefore advise against using sealing tape.
We recommend sealing by using the integrated o-ring above the thread.
When using the weld-on coupling (accessory 1086-01, see
data sheet), the measuring tip is sealed directly using an o-ring
The upper seal at the hexagonal part has then no function.
INTENDED APPLICATION
The switch is designed for level monitoring of liquids. Operation is only
intended with the specifications stated on the product label.
CLEANING
The measuring device is maintenance-free.
Certain media can cause build-up and clogging of the sensor. Accumu-
lated deposits can lead to incorrect measurements. In the case of media
that tend to form deposits, the sensor must be cleaned regularly, for
example with clear water. Do not use sharp or hard tools or corrosive
chemicals to clean the sensor.
TECHNICAL DATA
Housing material / tip
Electrical connection
Process connection
Tightening Torque
Power supply
Output Voltage
Protection type
Max. pressure
Revision: 06 / 2023 A
Technische Änderungen vorbehalten
Subject to change without prior notice
Nöding Messtechnik GmbH • Oldenfelder Bogen 29 • D-22143 Hamburg, Germany • Tel.: +49 40 67 58 51 – 0
Fax: +49 40 67 58 51 – 49 • Internet: www.noeding-messtechnik.de • E-mail: info@noeding-messtechnik.de
Stainless steel 1.4404 / PEEK
see label
G1/2A, ISO 228-1
max. 10 Nm
9...30 V DC
DC PNP, max. 200 mA
IP 67
16 bar
Further information can be found using
the QR code or at
www.noeding-messtechnik.de/FM2
ELEKTRICAL CONNECTION
M12 connector
PIN 1:
PIN 3:
PIN 4:
PIN 2:
Cable connection
rd:
bk:
wh:
br:
Quickon
PIN 1:
PIN 3:
PIN 2:
(or customerspecific
min-function on PIN 2)
DIMENSIONS
20
LED
27
G1/2A
18
Measuring tip
PEEK
When using the weld-on coupling (accessory
1086-01, see data sheet), the measuring tip is
sealed directly using an o-ring 13,5x1,5 Vi70.
The upper seal at the hexagonal part has then
no function.
in +
in -
out + Max
out + Min
in +
in -
out + Max
out + Min
in +
in -
out + max
20
27
G1/2
29,7