Betriebsanleitung Mikrowellen Schalter
Operating Instructions microwave switch
SAFETY NOTES
If  the  device  is  used  incorrectly,  application  related  dangers  may  arise. 
The transmitter must be installed, connected, commissioned, operated 
and  maintained  by qualified and authorised personnel only  and  un-
der strict  observance of these operating instructions,  relevant  national 
standards, legal requirements, and where appropriate, the product cer-
tification. 
INSTALLATION
For  unrestricted  functionality,  there  must  be  a  good  electrically  con-
ductive  connection  between  the  sensor  and  the  container  housing. 
We therefore advise against using sealing tape.
We recommend sealing by using the integrated o-ring above the thread.
When  using  the  weld-on  coupling  (accessory  1086-01,  see 
data  sheet),  the  measuring  tip  is  sealed  directly  using  an  o-ring 
The upper seal at the hexagonal part has then no function.
INTENDED APPLICATION
The switch is designed for level monitoring of liquids. Operation is only 
intended with the specifications stated on the product label.
CLEANING
The measuring device is maintenance-free.
Certain media can cause build-up and clogging of the sensor. Accumu-
lated deposits can lead to incorrect measurements. In the case of media 
that  tend  to  form  deposits,  the  sensor  must  be  cleaned  regularly,  for 
example with clear water. Do not use sharp or hard tools or corrosive 
chemicals to clean the sensor.
TECHNICAL DATA
Housing material / tip
Electrical connection
Process connection
Tightening Torque
Power supply
Output Voltage
Protection type
Max. pressure
Revision: 06 / 2023 A
Technische Änderungen vorbehalten
Subject to change without prior notice
Nöding Messtechnik GmbH  •  Oldenfelder Bogen 29  •  D-22143 Hamburg, Germany  •  Tel.: +49  40  67 58 51 – 0
Fax: +49  40  67 58 51 – 49  •  Internet: www.noeding-messtechnik.de  •  E-mail: info@noeding-messtechnik.de
Stainless steel 1.4404 / PEEK
see label
G1/2A, ISO 228-1
max. 10 Nm
9...30 V DC
DC PNP, max. 200 mA
IP 67
16 bar
Further information can be found using
the QR code or at
www.noeding-messtechnik.de/FM2
ELEKTRICAL CONNECTION
M12 connector
PIN 1: 
PIN 3: 
PIN 4: 
PIN 2: 
Cable connection
rd: 
bk: 
wh: 
br: 
Quickon
PIN 1:  
PIN 3:  
PIN 2:  
(or customerspecific
min-function on PIN 2)
DIMENSIONS
20
LED
27
G1/2A
18
Measuring tip
PEEK
When  using  the  weld-on  coupling  (accessory 
1086-01, see data sheet), the measuring tip is 
sealed  directly  using  an  o-ring  13,5x1,5 Vi70. 
The upper seal at the hexagonal part has then 
no function.
in +
in -
out + Max
out + Min
in +
in -
out + Max
out + Min
in +
in -
out + max
20
27
G1/2
29,7