Herunterladen Diese Seite drucken

clearaudio electronic Satisfy Kardan Aluminium black Bedienungsanleitung Seite 10

Vorschau ausblenden Andere Handbücher für Satisfy Kardan Aluminium black:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

User manual / Bedienungsanleitung
4. Adjustment of the distance between spindle and pivot point
We recommend to use the Clearaudio alignment gauge (Art. No. AC005/IEC, also available from
www.analogshop.de) for the exact setting of the tonearm pivot point.
Make sure that the distance between spindle and the pivot point of the tonearm is exactly 222mm.
You can adjust the distance by rotating the tonearm base.
Please tighten the tonearm base and check the measurement again after adjustment.
Pic. 7: Distance from pivot to stylus
5. Adjustment of the tonearm
The following settings require to mount the cartridge on the headshell.
Always follow the cartridge manufacturer's instructions.
Pic. 8: Mounting the cartridge
Connect the pins of your cartridge to the jacks of the tonearm cable, taking care not to use too
much force.
Use suitable precision pliers or tweezers for assistance if necessary.
Page / Seite 10
Leave the stylus protector on your cartridge to avoid any
damages!
Now you can connect the respective signal cable with the matching
color pins of the cartridge.
Please note the following colour coding:
Red:
right channel / R+
Green:
right channel / R-
White:
left channel / L+
Blue:
left channel / L-
© clearaudio electronic GmbH, 2023-10

Werbung