Herunterladen Inhalt Inhalt Diese Seite drucken

ACO Haustechnik Lipatomat-VA Gebrauchsanleitung Seite 60

Frischfettabschneideranlage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fresh grease separator plant Lipatomat-VA + -PE
Installation
Ventilation line
Requirements:
Lay the ventilation line up to above the roof. Ventilate connection pipes longer than 5 m
separately.
If the inlet pipe above the grease separator has no separately ventilation connection
pipe over 10 m length, it must be equipped with an additional vent stack as close as
possible to the grease separator.
Instead of an additional connection in the inlet pipe near the grease separator, the
connection port of the ventilation bridge of the Lipatomat VA can be used instead.
Ventilation valves are not permitted in areas at risk of backflow or for ventilating the
grease separator.
Lay ventilation lines made of materials resistant to fatty acid (e.g. KML, PP, PE).
Lipatomat VA:
Nominal diameter of the connection port: DN 100 – OD 110 mm.
Decide on the connection to the
Î
ventilation bridge: right or left.
Remove the end cover.
Î
Connect the on-site ventilation line (4).
Î
Lipatomat PE:
Connect the on-site ventilation line in the
Î
on-site inlet pipe (4).
60/ 84
10
Frischfettabscheideranlage
Lipatomat VA
9
Legende:
1 = Steuerung
2 = Füllstandsgrenzmelder/
Schlamm-Sammelbehälter
3 = Kompressor
4 = Pneumatischer Kugelhahn/
8
1
Schlammabzug
7
5 = Füllstandsgrenzmelder/
6
Fett-Sammelbehälter
6 = Heizstab
5
2
7 = Pneumatischer Kugelhahn/
4
Fettabzug
8 = Fettsonde
3
9 = Krählwerk
10 = Magnetventil/Fülleinheit
H
0
A
H
0
A
H
0
A
H
0
A
H
0
A
Krählwerk/
Heizstab/
Kugelhahn Fettabzug/
Kugelhahn Schlammabzug/
Magnetventil Fülleinheit/
Agiating device
Heating rod
Ball valve for grease draw-off
Ball valve for sludge draw-off
Solenoid valve for filling device
9
6
7
4
10
Reset
Reset
H
= Hand/Hand
0
= Aus/Off
A
= Automatik/Automatic
Fett-Sammelbehälter voll/
Schlamm-Sammelbehälter voll/
Störung/
Grease collecting barrel full
Sludge collecting barrel full
Hauptschalter/
Malfunction
main switch
5
2
DC_0150.66.62_V1.0
ACO Service
Tel.: + 49 (0) 36965 819-444
Im Gewerbepark 11c
Fax: + 49 (0) 36965 819-367
36457 Stadtlengsfeld
service@aco.com
www.aco.com
10
Legende:
1 = Steuerung
9
2 = Füllstandsgrenzmelder/
Schlamm-Sammelbehälter
3 = Kompressor
Schlammabzug
4 = Pneumatischer Kugelhahn/
6 = Heizstab
Fett-Sammelbehälter
5 = Füllstandsgrenzmelder/
7
8
1
7 = Pneumatischer Kugelhahn/
Fettabzug
5
6
2
10 = Magnetventil/Fülleinheit
8 = Fettsonde
9 = Krählwerk
4
3
H
A
0
H
0
A
H
0
A
H
0
A
H
0
A
Krählwerk/
Agiating device
Heating rod
Heizstab/
Ball valve for grease draw-off
Kugelhahn Fettabzug/
Ball valve for sludge draw-off
Kugelhahn Schlammabzug/
Solenoid valve for filling device
Magnetventil Fülleinheit/
9
6
7
4
10
Reset
Reset
H
= Hand/Hand
= Automatik/Automatic
0
= Aus/Off
A
Fett-Sammelbehälter voll/
Schlamm-Sammelbehälter voll/
Störung/
Grease collecting barrel full
5
Sludge collecting barrel full
2
main switch
Hauptschalter/
Malfunction
ACO Service
Im Gewerbepark 11c
Tel.:
+ 49 (0) 36965 819-367
Fax:
+ 49 (0) 36965 819-444
36457 Stadtlengsfeld
service@aco.com
www.aco.com

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lipatomat-pa

Inhaltsverzeichnis