2.1.2 Performance
Battery Unit 7H
Electrical Characteristics
Total Energy Capacity
Usable Energy Capacity
Battery Capacity
2
Voltage Range
Absolute Max. Voltage
Max. Charge/Discharge Current
Max. Charge/Discharge Power
3)
Peak Power
(only discharging)
Peak Current (only discharging)
Communication Interface
DC Disconnect
Connection Method
User interface
Operating Conditions
Installation Location
Operating Temperature
Operating Temperature (Recommended)
Storage Temperature
Humidity
Altitude
Cooling Strategy
Noise Emission
Certification
Total Energy Capacity
Emissions
Hazardous Materials Classification
Transportation
Ingress Rating
1)
Charge
Discharge
2)
Cell
UL1642
Battery Pack
TUV(IEC 62619) / CE(IEC 60950-1) / RCM
IEC 61000-6-1 / IEC 61000-6-3
Class 9
UN38.3
IP55
7 kWh@25°C (77°F), 100% SOE
6.6 kWh
63 Ah
400 to 450 VDC
350 to 430 VDC
520VDC
8.5 A@420V / 14.3A@350V
3.5 kW
5 kW for 5 sec.
13.5 A@370V for 5 sec.
RS485
Circuit Breaker
Spring Type Connector
LEDs for Normal and Fault operation
Indoor / Outdoor (Wall-Mounted)
-10 to 45 °C (14 to 113 °F)
15 to 30 °C (59 to 86 °F)
-30 to 55°C (-22 to 131°F)
5% to 95%
Max. 2,000m (6,562 ft)
Natural Convection
< 40 dBA