Herunterladen Diese Seite drucken

Auer Signal MPL Anwendung Seite 3

Werbung

Assembly and installation
(without the mounting plate)
L oosen the screws of the cover and
remove the cover. Insert four 4 mm
screws with a head diameter of 6 to
7 mm into the openings and mount
the lower part of the device on the
wall, ceiling or a panel. In case of
screws with a head diameter which
is too small, use the appropriate
washers with a diameter of 6 to 7 mm.
L ead the connection cables through
the cable glands and connect them
to the terminal clamps. The clamps
are disposed in 3 blocks in the
terminal compartment (corresponding
to L , N and earth). The three clamps
of each block are bridged. You can
connect up to 3 devices.
Only use wires with an outer diameter
of Ø8 to 1 5.5 mm, the IP66 rating
of the device cannot be otherwise
guaranteed. The cable glands must
be tightened using a tightening
torque of 2.5 to 3.5 Nm.
The cover screws must be tightened
using a tightening torque of 1 .2 Nm.
The terminal box can be installed in
any position.
Assembly and installation
(with the mounting plate)
Mount the mounting plate on the wall
using four screws with a diameter
of 6 to 8 mm. Choose the right
screws with the appropriate length
depending on the surface bearing
capacity.
The possible mounting positions
of different signalling devices on
the mounting plate are presented in
the mounting plan. The devices are
connected according to the relevant
device instructions.
L oosen the cover screws of the
terminal box and remove the cover.
L ead the connecting cables through
the cable glands and connect them
to the terminal clamps. The clamps
are disposed in 3 blocks in the
terminal compartment (corresponding
to L , N and earth). The three clamps
per block are bridged. You can con-
nect up to 3 devices.
Only use wires with an outer diameter
of Ø8 to 1 5.5 mm, the IP66 rating of
the device cannot be otherwise guar-
anteed. The cable glands must be
tightened using a tightening torque of
2.5 to 3.5 Nm.
T he cover screws must be tightened
using a tightening torque of 1 .2 Nm.
Tighten the earth clamps using a
tightening torque of 2 Nm.
The correct mounting position is
determined depending on the devices
used.
Mounting accessories for signal-
ling devices (6 M6x1 6 screws with
self-locking nuts) are included.
Instructions on the cable
glands and blanking plug
The cable gland must comply with
the
requirements
on
protection, temperature rating of
-40°C Ta +70°C and IP66 rating.
Use only the correct tools for the
assembly of the cable connections
and the cable gland!
The cable gland can only be used for
fixed cable routing.
Observe the following when mounting
the blanking plug:
1 . Only use the appropriate blanking
plug for the cable gland.
2. The head part of the blanking plug
Technical Data
Clamping capacity
Type of protection:
Nominal voltage
Maximum current
Operating temperature
Transport and storage temperature:
Operating position
Dimensions
(Wx H x D)
Dimensions incl. Mounting plate
Weight without the mounting plate
Weight with the mounting plate
Name
Auer Signal GmbH
Perfektastraße 102, A-1230 Vienna
Type MPL
Item no. XXXXXXX
BVS 1 5 ATEX E 027
II 2G Ex e IIC T4 Gb
II 2D Ex tb IIIC T1 35°C Db
CE 0408
-40°C
Ta
+65°C
U
= 230 V I
= 5 A
n
max
Serial number XXXX
WARNING – Observe the operating instructions of connected devices
WARNING – Take into account the instructions of the connected equipment
Service
Products are subject to strict quality control during manufacturing.
Damages caused during transport or assembly can affect the operation
of the device. When putting into service, check the correct operation
of the device, and perform regular maintenance to ensure the correct operation
thereafter.
If you have any questions concerning the device, or in the event of a fault,
even after the warranty period, please contact .
number and item number at hand (you can find these on the rating plate).
must be on the outside.
3. Insert the blanking plug fully into
the cable gland and tighten it with
a tightening torque of 3.5 Nm.
Maintenance
The type MPL terminal box contains
no serviceable parts. The require-
ments of EN 60079-1 7 regarding
the regular control of the explosion
explosion
protection must be applied.
Note on environmental
protection
• The packaging must be disposed
of in an environmentally friendly
manner.
• The device is disposed of as
electronic waste.
Plastic, metal and electronic parts
are to be disposed of separately
upon disassembly by a professional
authorized party according to the
national requirements.
up to 4 mm stranded or solid wire
II 2G Ex e IIC T4 Gb
II 2D Ex tb IIIC T1 35°C Db
Un = 230 V
Imax = 5 A per wire of 1 ,5 mm2
-40°C to +65°C according to IEC 60721
-40°C to +70°C according to IEC 60721
optional
approx. 1 90 mm x 75 mm x 75 mm
approx. 440 mm x 1 80 mm x 1 64 mm
(Wx H x D)
approx. 0.6 kg
approx. 2.6 kg (3.5 kg incl. Packaging)
IP66
IK08
Check: Month / Year / Tester
Please keep the type
3

Werbung

loading

Diese Anleitung auch für:

Mpl mit montageplatte