9 Operation
After installation, is important to check the corrective function to safety socket outlet. Press the
Reset button, and then press the test button, the unit must trip. In addition, check with a suitable
tester that the power is actually switched off.
Safety socket outlet must not be used if it has not passed this function test.
Test the function of the safety socket from time to time e.g. every month.
The test can be carried out as follows:
1. Press the Reset Button.
2. Press the Test Button, the unit must trip.
3. Press the Reset Button again.
The user must ensure that the equipment is suitable for the intended operating conditions

at the point of use, operating position, climatic conditions.
Damaged electrical equipment must not be used. Particular attention must be paid to

kinked or damaged cables.
Improper use (e.g. pulling the connector at the cable, dropping from a great height, throw-

ing, ect.) is not permitted.
In order to minimise wear of connectors and sockets, we recommend that electrical con-

sumers be unplugged / disconnected when switched off.
If the system allows connectors of a certain IP connection class to be inserted in plugs of

another IP protection class, then the fact that the resulting IP protction class of the connec-
tor/ socket combination corresponds to the lower of the two must be taken into account.
Any use of the Personal protection socket equipment going beyond use for the intended

purpose will void all guatantee, warranty and/or liability claims.
10 Troubleshooting
Problem
Possible cause
The personal protection
Imperfect electrical contact.
socket does not work.
11 Disposal
This symbol must appear on any electrical and electronic equipment placed on the
EU market. This symbol indicates that this device should not be disposed of as
unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back
of waste. Conrad provides the following return options free of charge (more details on our
website):
in our Conrad offices

at the Conrad collection points

at the collection points of public waste management authorities or the collection points set

up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in
countries outside of Germany.
12 Technical data
12.1 Power supply
Input voltage/current ..................... 220 - 240 V/AC, 50/60 Hz, 16 A
Max. load ...................................... 3600 W
Rated current ................................ 16 A
Rated residual current .................. 30 mA
Response time .............................. <30 ms
Cable cross-section ...................... 1.5 mm² or 2.5 mm²
12.2 Environment
Operating temperature ................. -20 °C to +40 °C
Storage temperature ..................... -20 °C to +40 °C
Humidity range ............................. Not more than 95%
12.3 Other
Dimensions ................................... 69 x 86 x 87 mm (D x W x H)
Weight .......................................... 190 g
Cable cross-section ...................... 1.5 mm² or 2.5 mm²
Weight .......................................... 130 g
Suggested solution
Check and reconnect
contacts.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
*2887576_V1_0923_02_m_VTP_4L

Werbung

loading