Herunterladen Diese Seite drucken

Sygonix 2886554 Bedienungsanleitung Seite 5

Elektrischer wasserhahn mit durchlauferhitzer 3000 w

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Only connect the mains plug to a mains outlet protected by a residual current device
(RCD) having a rated residual operating current not exceeding 30 mA.
Installation diagram:
I
H
G
F
E
D
C
A
Installation surface
C
Water supply line
E
Bottom spacer
G
Top spacer
I
Spout
Installation procedure:
WARNING
Water conducts electricity
Risk to life by electric shock
● Keep hands and workplace dry
● Connect to water line before connecting to mains supply.
● Disconnect from mains supply before disconnecting from water line.
1. (If connected) disconnect the mains plug of the faucet from the mains supply.
2. Close the water supply to the water supply line (C).
3. Remove the protective cap from the water inlet (B).
4. Assemble and install the faucet as shown in the installation diagram. Rotate and tighten
the hand nut (D) to lock the faucet in place.
5. Connect the water supply line (C) to the water inlet (B). Use sealing tape if needed.
6. Rotate the faucet lever (H) to the position OFF to close the faucet.
7. Slowly open the water supply to the water supply line.
8. Check for water leaks. Remedy water leaks before you proceed.
9. Carefully rotate the faucet lever to run water. Check that water runs unobstructed.
10. Rotate the faucet lever to the position OFF to close the faucet.
11. Connect the mains plug to the splash-proof mains socket.
à
The faucet is installed and ready for use.
5
A
B
B
Water inlet
D
Hand nut
F
Rubber pad
H
Faucet lever
8 Operation
The product has an integrated dry-run protection. The heater only kicks in when water flows
through.
Use the faucet lever to control the flow rate and water temperature.
The water temperature is displayed on the water temperature display.
Max. cold water flow
Low water flow
Max. hot water flow
9 Troubleshooting
Problem
Possible cause
Display is on.
Water flow is too low.
Does not heat.
Display is on.
Overheat protection was
triggered.
Does not heat.
Display is off.
Product is damaged.
Does not heat.
Low water temperature
Water flow is too great.
Low water temperature
Input voltage is too low.
High water temperature
Water flow is too low.
High water temperature
Water intake is blocked.
9.1 Resetting overheat protection
The resettable overheat protection shuts the product off if it overheats. Reset the protection
to continue using the product.
R
1. Let the product cool down room temperature.
2. With a flat-head screw driver, push up the boss (R) to reset the overheat protection.
à
You have reset the overheat protection.
à
You can use the product again.
10 Cleaning
Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
They damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.
1. Disconnect the product from the power supply.
2. Clean the product with a dry, fibre-free cloth.
3. Clean the faucet body, spout and aerator, if necessary. Use a natural limescale remover
(example: cleaner with citric acid). Thoroughly rinse the cleaned parts with clear water.
OFF
Suggested solution
Increase water flow with
faucet lever.
Follow instructions in "Reset-
ting overheat protection" to
reset the overheat protec-
tion.
Contact a specialist to in-
spect product for damage.
Reduce water flow with
faucet lever.
Refer to "Technical data" for
required input voltage.
Increase water flow with
faucet lever.
Check water intake for block-
ages.

Werbung