Herunterladen Diese Seite drucken

Pentatech SL 02 Bedienungsanleitung Seite 6

Zufallsschalter

Werbung

c
Danger!
Before installing the device, please turn the power supply off. Ensure that the
lamp socket is not live during installation and that nobody can turn the power on
again while the device is being installed.
It is important to ensure that there is sufficient safety clearance between the illu-
minant and other items. It is possible that when the device is fitted the clearance
to combustible materials such as lampshades etc. is reduced.
Do not open the device. The voltage inside the device is high! Otherwise there is a
possibility of electric shock and a danger of death!
Do not insert any objects into the socket or device, as otherwise you might touch
live parts! Danger of electric shock, fire or death!
It is essential to ensure that the device does not come into contact with water or
moisture. Otherwise there is a danger of electric shock, fire or death!
The device should only be cleaned with a dry or slightly damp cloth, keeping the
bayonet cap and socket dry. Otherwise there is a danger of electric shock or death.
The device should not be left in the hands of children. It is not a toy. Otherwise
there is a danger of death!
Do not leave the packaging material lying around. Plastic parts etc. might become
a dangerous toy for children. There is a danger of death through suffocation!
m
Caution!
Please avoid exposing the device to the following: strong mechanical stresses,
extreme temperatures, strong vibrations, strong magnetic or electric fields.
Do not open the device. Maintenance is not necessary and repairs are not possible.
Fields of Application and Function
The light controller could help to deter burglars by indicating that you are at home by
switching lights on and off automatically.
To this purpose the light controller is screwed into the lamp socket and afterwards the
illuminant into the light controller.
Two types of simulation are possible:
o
Dusk to dawn switch: When it becomes dark outside the light switches on auto-
matically (after a short delay) and switches off again at daybreak.
o
Random switch: The random generator switches the light on and off automati-
cally during the night at irregular intervals. On average the light is illuminated for
about 80% of the time during the first half of the night and for about 20% of the
time during the second half.
The light can be switched on and off normally.
Requirements
The light controller should be used with a light socket with an E27 screw and an appro-
priate illuminant which also has an E27 screw. The light fitting must be controlled by a
switch and be voltage-free in the switched off condition.
Appropriate Illuminants:
o
Bulb, min. 40 W to max. 100 W (in the case of closed lampshades max. 60 W)
o
Energy-saving lamp, min. 7 W to max. 23 W
The following illuminants should not be used:
o
Lamps controlled by a dimmer switch
o
Lights recessed into the ceiling, flicker and glow lamps
Installation
Q Lamp socket
W Screw cap
E Light controller
R Screw fitting for bulb
T Bulb
o
Before installation please turn off the light.
o
Before installation please turn off the power supply.
Note the safety instructions.
o
Unscrew the existing bulb from the socket Q .
o
Insert the light controller E with the screw cap W
into the lamp socket Q and turn in a clockwise direction.
o
Insert the bulb T into the socket R and turn in a clockwise direction.
c
Danger! It is possible that when the light controller is used the distance to com-
bustible materials such as a lamp shade etc. will be reduced. Please ensure that
there is sufficient safety clearance!
If the lamp shade is closed the maximum power of the bulb must be 60 W!
Open lamp shade
Please also note the instructions of the lamp manufacturer.
Operation
After installation of the light controller you can turn the light on and off as before.
Activation of the Dusk to Dawn Switch Function
o
Turn the light on and off and then on again quickly: The light flashes once briefly
as confirmation.
o
The dusk to dawn switch function is now activated.
After it has become dark outside and the automatic program delay of approximately
2 minutes has expired, the light controller automatically turns the light on. At daybreak
the light goes off automatically with a delay of up to 45 minutes.
When the light is switched on it is turned off automatically for about 1 second
approximately every 45 minutes in order to check the surrounding brightness.
o
The twilight switch function remains on until deactivation, i.e. the light is switched
on every night.
Q
W
E
R
T
Closed lamp shade

Werbung