Herunterladen Diese Seite drucken

WellerFT LASERLINE 150 Originalbetriebsanleitung Seite 21

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Filter change
Warning!
Before doing any work on the
machine, pull the plug out of the
socket.
Warning!
Use original replacement parts only.
The unit must not be altered or modi-
fied in any way!
Repairs must always be referred to a
Weller-trained specialist.
The normal service life of a main
MIN 1x
filter in the electronics industry is
1500 hours.
The main filter should be chan-
year
ged at least once a year in order
to ensure proper gas separation.
Contaminated filters must be treated as special
waste.
Dispose of replaced equipment parts, filters
or old devices in accordance with the rules
and regulations applicable in your country.
Wear suitable protective gear.
Cleaning
To ensure that the unit functions properly, the nozzle, extractor arm and connecting hose must be clea-
ned on a regular basis.
Error messages and error clearance
Message/symptom
Extraction power missing
Loud extraction noises
Unit is not running
Device does not work
北京海洋兴业科技股份有限公司(证券代码:839145) 电话:010-62176775
The normal service life of a main filter in the electro-
nics industry is 1500 hours.
The main filter should be changed at least once a
year in order to ensure proper gas separation.
The degree of clogging of the filter is determined by
differential pressure measurement. The filter display
indicates the current condition of the filter.
An alarm sounds and the yellow warning light
flashes: Recommended service life of filter has
expired. (see Operating time filter display/Extrac-
tion capacity filter display)
An alarm sounds and the red warning light is
lit continuously: Extraction capacity is too low.
Switch off the filter unit. Check the nozzles, tubes
and extractor arms, and clean them if necessary.
If the alarm sounds again the next time the unit is
turned on, the filter must be changed.
If no action is taken, the filter unit will cut out after
five minutes in order to avoid overheating.
When changing the main filter the filtration time
can be reset as follows:
Keep the UP/DOWN buttons pressed and, at the
same time, turn on the switch until an audible
signal sounds. Release the buttons, wait 5s and
turn the unit off. Wait another 5s and turn the unit
on. Filtration time is now reset.
Possible cause
Pipe system leaking
Filter is dirty
Turbine speed too low
Air speed through extraction-
arm is too high speed
Thermally switched off
Fuse is blown
Unit is not properly connected
Remedial measures
Reseal the pipe system
change the filter
Increase the speed setting
Reduce the air speed (reduce air
quanitity)
Leave the unit to cool down.
Switch on again after approx. 3
hours.
Please contact our Customer
Service: technical-service@
weller-tools.com
Check the electrical connections
网址:www.hyxyyq.com
19

Werbung

loading

Verwandte Produkte für WellerFT LASERLINE 150

Diese Anleitung auch für:

Mg140Ft-l-15145-1000-esd