Quick Start Guide
Differential Charge Amplifier and Data Acquisition Device
Type 5166A...
Foreword
Thank you for choosing a Kistler quality product. Please read these
instructions carefully, so that you can take optimum advantage of the
versatile features of this product.
The information in this document is subject to change at any time
without prior notice. Kistler reserves the right to improve and modify
the product in accordance with technical progress without the obli-
gation to inform persons and organizations based on these changes.
© 2023 Kistler Group. All rights reserved. Kistler Group products are
protected by various intellectual property rights. For more details visit
www.kistler.com.
Content
1.
General Information
2.
Device Description
3.
Connection Setup via Ethernet
4.
Control via Web Interface, Instruction Manual
5.
Activation of purchased Software Features
6.
Restoring all Settings
7.
Repairs at Kistler
8.
Disposal Instructions for Electronic Devices
1.
General information
The Kistler LabAmp Type 5166A... differential charge amplifier and
data acquisition device can be used wherever mechanical quantities
are measured with piezoelectric sensors with differential output.
Signals from the piezoelectric sensor are digitized and processed
with high resolution. Data acquisition as well as freely configurable
analog outputs emphasize the comprehensive application options of
the device.
The laboratory measuring amplifier is configured as well as operated
with an intuitive web interface that is easily available through an
external computer via a standard web browser. The web browser-
based data download permits easy further processing of the acquired
signals in an analysis software. The present instructions are for rapid
commissioning of the device.
For initial commissioning of the device, see chapter 3.
2.
Device Description
The following brief description explains the basic components of the
measuring amplifier and refers to the corresponding chapters with
more detailed descriptions:
Front side – Type 5166A...
Back side – Type 5166A...
Description
Connector of the 24 V power supply
(e.g. plug-in power supply unit)
Main switch for the power supply of the device
Sensor inputs: LEMO EEP.1E.304
Analog outputs: BNC neg.
Light-emitting diodes (LEDs), indicating the status of the
corresponding sensor input or analog output
Remote control connector (D-Sub 9-pole neg.)
• Measure/Reset control (Pin 5)
• Start/Stop trigger (Pin 4)
• 24 V supply (Pin 1)
• GND (Pins 2 & 6)
USB ports (not yet supported): 2x USB
2 Ethernet interfaces (RJ45) with switch functionality for
connection to a network or computer
Reset button for resetting the device to factory settings
Ground lug
Fold-out feet
Status LED (E)
The LEDs indicate the status of the corresponding sensor input or
analog output and the general operating statuses of the device. The
table below shows the possible statuses:
5166A_012-056e-08.23
LED Status
Blue
illuminated
Red
Illuminated
Switched off
LEDs are illuminated in
yellow from left to right
Yellow flashing
3.
Connection Setup via Ethernet
The measuring amplifier Type 5166A... includes an integrated web
server, whose web interface is used to operate the device. Please
ensure that your PC is in DHCP mode and/or Auto-IP mode (net-
work settings).
The following approach is recommended to establish a connection
with the measuring amplifier via Ethernet:
1. Connect the Device to the Network
Connect the measuring amplifier (connector H –> Sync In or Sync
Out) via a network cable directly to a computer or a network (e.g.
network switch).
2. Find the Device in the Network
a. Start the „Network Setup Wizard" tool that finds all Kistler
network devices (tool can be found under www.kistler.com in
the download area of the Kistler LabAmp Type 5166A).
b. Click on „Network Setup Wizard" and wait until Kistler net-
work devices are displayed. In the case of a direct connection,
it may take up to 2 minutes until the devices are displayed.
c. The table displays now all identified Kistler network devices.
3. Access to the Device via Web Browser
Choose your device in the table by clicking on the table entry and
select one of the following two options:
a. "Open Browser"
Opens the web interface of the respective device in a standard
web browser. The measuring amplifier can now be configured
and operated via the web interface (–> Chap. 4).
b. "Identify"
Permits an identification of the respective device. The identi-
fied measuring amplifier signals this through the yellow flash-
ing of all LEDs for approx. 4 s (–> Chap. 2). This function
is very useful if several measuring amplifiers are used in the
same network.
Operating Status
Sensor input is measuring/
analog output is active
Error (e.g. range overflow)
Analog output is switched off,
0V at the output
Initialization after switch-on of
the device or software update
Temporary status (e.g. device
identification, read TEDS, etc.)
Adapting Network Settings:
The network settings for the marked device can be adapted by
clicking on „Next". The following options can be configured for this
purpose:
• Device name:
The device name is displayed in the "Network Setup Wizard" as
well as in the web interface. In networks that support name reso-
lution, the device name can be entered directly in the address
field of the web browser to access the device.
• Address mode:
The address modes "DHCP with Auto-IP" and „Static IP" are
supported.
Information Regarding Network Connection:
The "Network Setup Wizard" finds Kistler network devices
throughout the network. However, if there are several rout-
ers or switches between the computer and the measuring
amplifier, this search might not be successful under certain
circumstances.
4.
Control via Web Interface, Instruction Manual
The measuring amplifier is operated via the web interface. After the
first connection with the device (–> Chap. 3), the home screen is
displayed.
The user manual which describes all the functionality of the web
interface is accessible by clicking on the "i" in the upper right corner
of the web interface.
5.
Activation of purchased Software Features
To activate purchased software features, it is recommended to con-
nect the device to a computer or network with Internet access (online
activation). If the network installation does not allow this, an offline
activation (device without access to the Internet) is also possible.
Online Activation
For the online activation of purchased software features, proceed
as follows:
1. Establish connection to the device via Ethernet, if not already
done ( –> Chap. 3)
2. Click on „Manage Licenses" in the LabAmp web interface
under menu „Maintenance" – „Software Licensing"
3. Click "Add new license", enter Ticket-ID and confirm with
„Next"
4. Note „License activated" appears and can be confirmed with
"Close"
Offline Activation
To activate purchased software features offline, proceed as follows:
1. Establish connection to the device via Ethernet, if not al-ready
done ( –> Chap. 3)
2. Click on „Manage Licenses" in the LabAmp web interface
under menu „Maintenance" – „Software Licensing"
3. Confirm note „License Activation" with „Next"
4. Follow the instructions until the activation is complete
6.
Restoring all Settings
The device can be reset to the factory settings by using the reset
button (I). This causes all user and network settings to be reset. To
reset the settings, the reset button (I) on the back of the device must
be actuated with a pointed object (e.g. needle) for at least 2 seconds.
7.
Repairs at Kistler
Repairs at the Kistler factory can be arranged via the local sales
company.
Information can be found at www.kistler.com
8.
Disposal Instructions for Electronic Devices
Old electronics devices may not be disposed
of with household refuse/residual waste.
Please return obsolete devices to the nearest
electronics disposal center for disposal or con-
tact your Kistler Sales Representative.

Werbung

loading

Inhaltszusammenfassung für Kistler 5166A Serie

  • Seite 1 (I) on the back of the device must be actuated with a pointed object (e.g. needle) for at least 2 seconds. Repairs at Kistler Repairs at the Kistler factory can be arranged via the local sales company. Information can be found at www.kistler.com Back side –...
  • Seite 2 Betriebsstatus Blau Sensoreingang misst / Vorwort leuchtend Analogausgang ist aktiv Wir danken Ihnen, dass Sie sich für ein Kistler Qualitätsprodukt Aktivierung von erworbenen Software-Features entschieden haben. Bitte lesen Sie diese Anleitung sorgfältig durch, Fehler (z.B. Bereichsüberlauf, leuchtend etc.) damit Sie die vielseitigen Eigenschaften Ihres Produkts optimal nut- Für die Aktivierung von erworbenen Software-Features wird...