Herunterladen Diese Seite drucken

Werbung

1. OPENING THE LOCK
1.1. Press«ON» – single acoustic signal and green LED;
1.2. Enter master or user code, consisting of 6...8 symbols (master code
set up in the factory, 1-2-3-4-5-6, the user code is not activated);
1.3. Press«ENTER». After the green LED is activated the lock is ready to
open during 5 seconds.
2. PROGRAMMING
2.1 Master-code programming:
• Press «ON»;
• Press «ENTER»;
• Press «1»;
• Press «ENTER»;
• Enter valid master-code and press «ENTER»;
• Enter new master-code (6 symbols minimum, 8 symbols maximum)
and press«ENTER»;
• Enter new master-code again and press «ENTER».
A correct input of the valid or new master-code followed by a double
acoustic signal and green LED. An incorrect input of the actual or new
master-code followed by a single long beep and red L.E.D..
2.2 User-code programming (using master-code)
• Press «ON»;
• Press «ENTER»;
• Press «2»;
• Press «ENTER»;
• Enter valid master-code and press«ENTER»;
• Enter user-code (6 digits minimum and 8 digits maximum) and
press«ENTER»;
• Enter user-code again and press «ENTER».
2.3 User-code programming (without using master-code)
• Press «ON»;
• Press «ENTER»;
• Press «3»;
• Press «ENTER»;
• Enter valid user-code and press«ENTER»;
• Enter new user-code (6 minimum, 8 maximum) and press «ENTER»;
• Enter new user code again and press «ENTER».
2.4 Deleting the user-code
• Press «ON»;
• Press «ENTER»;
• Press «0»;
• Press «ENTER»;
• Enter valid master-code and press«ENTER»;
The user code is deleted, only the master-code is valid.
2.5 Dual code programming (master code and user code must al-
ready be programmed to enable this function)
• Press «ON»;
• Press «ENTER»;
• Press «7»;
• Press «ENTER» (If only master code is active, there will be a short
acoustic signal and red LED will be turn on. The lock will then turn off,
and the red LED will no longer be visible).
• Enter valid master code and press «ENTER»;
2.6 Opening the lock using dual code function:
• Press «ON»;
• Enter valid master code;
• Press «ENTER»;
2.6.1 There will be a short acoustic signal accompanied by green LED.
2.6.2 During the next 60 seconds with intervals of 5 seconds there will be
short acoustic signals accompanied by green LED. During this time a valid
user code must be entered, followed by «ENTER».
2.6.3 If the user code is entered correctly, the lock will open, accompanied
by a short acoustic signal and green LED.
2.6.4 If the user code is not entered or is entered incorrectly during the
60 seconds, there will be a long acoustic signal accompanied by red
LED. The lock then powers down and the opening procedure has to be
FS1920E OPERATING INSTRUCTION
Phoenix Safe Company
where peace mind is guaranteed
& GUARANTEE REGISTRATION
repeated from the beginning.
2.6.5 If the master code is entered incorrectly, there will be a long acoustic
signal accompanied by red LED. The lock then powers down.
2.7 Turning off Dual Code:
• Press «ON»;
• Press «ENTER»;
• Press «8»;
• Press «ENTER»;
• Enter valid master code and press «ENTER»
2.8 Programming of Time delay and Opening time window.
The time delay (TD) function refers to the period of time which must
elapse before the lock can be opened. The opening time window (OTW) is
the period during which the lock may be opened after the TD has elapsed.
Any valid code can be provided with a TD or OTW function.
• Press «ENTER»;
• Press «6»;
• Press «ENTER»;
• Enter valid user code or master-code and press «ENTER»;
• Enter a 2-digit number that will stand for the TD (01 -99 minutes) and a
number for the OTW (1-9 minutes). For example: 092 – 9 minutes for
TD, and 2 minutes – for the OTW.
Opening with the help of the programmed TD and OTW.
• Press «*»;
• Input valid user-code or master-code: green visual signal
• Automatic start of TD: red visual and acoustic signals every 5 seconds
• After end of TD – acoustic signal
• Automatic start of OTW: green visual and acoustic signal every 5
seconds
• Enter valid code once again during OTW: green visual signal
• By pressing «ENTER» during TD period this function is interrupted. The
entire sequence must then be repeated in order to open again.
Cancellation of programmed TD/OTW
• Press «ON» ;
• Press «ENTER» ;
• Press «6» ;
• Press «ENTER» ;
• Input valid user or master code and press «ENTER»;
• Input 0-0-0 for cancelation of TD and OTW.
2.9 Sound Off/ On
• Push «ON» button ;
• Push «ENTER» button ;
• Push «5» button ;
• Push «ENTER» button ;
• Input the actual master-code and push «ENTER» button; Acoustic and
light signals are the same as when programming the master-code.
3. INSUFFICIENT POWER SUPPLY
Low voltage is shown by the red LED and quintuple acoustic signal. There
is still sufficient energy for opening. Any change of code is not possible
whilst a low battery indication is displaying.
4. ERROR DIAGNOSES WHEN CHANGING THE ACTUAL
MASTER CODE.
This is the service function and it is indispensable for authenticity of the
master-code input.
• Push «ON» button;
• Push «ENTER» button;
• Push «4» button;
• Push «ENTER» button;
• Input the service-code «160400» and push «ENTER» button;
• If the lock has ever been opened with the help of the actual master-
code, after pushing «ENTER» button-quintuple buzz will follow and the
green L.E.D./ will blink 5 times.
V1 FEB 2019

Werbung

loading

Inhaltszusammenfassung für Phoenix FS1920E

  • Seite 1 FS1920E OPERATING INSTRUCTION & GUARANTEE REGISTRATION 1. OPENING THE LOCK repeated from the beginning. 2.6.5 If the master code is entered incorrectly, there will be a long acoustic 1.1. Press«ON» – single acoustic signal and green LED; signal accompanied by red LED. The lock then powers down.
  • Seite 2 BASE FIXING FOR THE FS1920 SERIES Signaux visuel et sonore sont les mêmes que lors de l’ouverture. La pro- Thank you for purchasing a Phoenix Safe. Your safe is ready prepared for grammation du nouveau ou valide code maître - Double signaux sonores base fixing / rear fixing (dependent on the model purchased), with fixing et voyant vert.
  • Seite 3 • Appuyez “ENTER” FIXATION AU SOL DE LA SÉRIE FS1920 • Appuyez “6” Merci d’avoir acheté un coffre-fort Phoenix. Votre coffre-fort est prêt pour • Appuez “ENTER” une fixation au sol/ fixation arrière (selon le modèle acheté), avec boulon- • Entrez un code utilisateur ou code maître valide et appuyez sur “...
  • Seite 4 FS1920E OPERATING INSTRUCTION & GUARANTEE REGISTRATION GERMAN 1. ÖFFNEN DES TRESOR • Drücken Sie die Taste „ENTER“; 1.1. Öffnen mit einem Benutzer- oder Mastercode • Geben Sie einen gültigen Benutzercode ein und drücken die Taste „ENTER“; • Drücken Sie die Taste „ON“ – Es ertönt ein akustischen Signal und •...
  • Seite 5 BODENVERANKERUNG, SERIE FS1920 verde. Errato inserimento di codice master valido oppure nuovo –(meno di Vielen Dank, dass Sie sich für ein Produkt aus dem Hause Phoenix Safe 6 simboli oppure oppure errata digitazione ripetuta). – singolo segnale acustico prolungato e L.E.D rosso.. Una sequenza errata viene indicata entschieden haben.
  • Seite 6 FS1920E OPERATING INSTRUCTION & GUARANTEE REGISTRATION 2.6.3 Se il codice utente digitato è corretto, la chiusura si aprirà, accompa- 4. DIAGNOSI DI ERRORE AL CAMBIO DEL CODICE gnata da un breve segnale acustico e da LED verde. MASTER ATTUALE. 2.6.4 Se il codice utente non viene inserito oppure viene inserito in modo Questa è...
  • Seite 7 INSTRUCCIONES DE MANEJO DE LA FS1920E Y REGISTRO DE GARANTÍA ESPAÑOL 1. APERTURA DE LA CERRADURA se apagará y el procedimiento de apertura deberá repetirse desde el 1.1. Pulse «ON»- Se oye una señal acústica individual y se ve una luz principio.
  • Seite 8 FIJACIÓN AL SUELO DE LA SERIE FS1920 Aus Sicherheitsgründen empfehlen wir Ihnen, Ihre Garantiekarte Gracias por comprar una Caja de Seguridad Phoenix. Su caja viene online auf unserer Website www.phoenixsafe.com per Mausklick preparada para su fijación al suelo o a la pared (dependiendo del modelo auf der Schaltfläche „Garantieanmeldung“...