Important Note to the Installer:
Please ensure that this document is passed to the user as it
contains important guidelines on operation, loading, cleaning
and general maintenance and should be kept for reference.
General Electrical Safety
Foster Refrigerator recommends that the equipment is electrically connected via a Residual
Current Device; such as a Residual Current Circuit Breaker (RCCB) type socket, or through a
Residual Current Circuit Breaker with Overload Protection (RCBO) supplied circuit.
Disposal Requirements
If not disposed of properly all refrigerators have components that can be harmful to the
environment. All old refrigerators must be disposed of by appropriately registered and licensed
waste contractors, and in accordance with national laws and regulations.
Start-Up and Test Sequence
After unpacking, clean and allow the cabinet to stand for 2 hours before turning on
(cleaning directions supplied within this manual). Ensure the cabinet is situated away from
both hot and cold air sources, as this will affect its performance. Make sure that a minimum
clearance of 150mm above the cabinet is available for ventilation and effective operation. Connect
the unit to a suitable mains power outlet and turn the supply on. Do not plug or unplug the unit
with wet hands.
Cabinets & counters are supplied ready for operation.
After connecting the unit to the mains the display will briefly show a dash in the centre of the
screen. This will then show
Press and hold the
released will start the 'Test Sequence').
To cancel the 'Test Sequence' press and release the
If not pressed the test will continue and when complete the controller will wait 1 minute, then
resume normal operation.
User Adjustments
To Check Storage Temperature Set Point
Press the
Manual Defrost
To initiate a manual defrost press and hold the defrost button for 2 seconds
Set Unit to Standby
When pressing the
This indication will be displayed while the unit is not operating but with mains power applied to the
unit. This mode may be used for interval cleaning regimes and short periods when the unit is not
required.
For extended periods of inactivity the mains supply should be isolated.
button for 3 seconds then release. (If pressed and held for 5 seconds then
button for at least half a second to display the set point.
button for 3 seconds, the unit will enter the standby mode and display
button during the test.