Important notices
The laser points to the location that will be measured.
No objects may get into the laser's line of measurement.
During the measurement, the device compensates for different
room temperatures. Therefore allow the device a brief adaptation
period when changing locations with large temperature differenc-
es.
The device is only conditionally useable in outdoor areas and
cannot be used in strong sunlight.
The measurement results of outdoor measurements may be influ-
enced or falsified by rain, fog and snow.
In unfavourable conditions, e.g. with poorly reflecting surfaces, the
maximum deviation may be greater than 3 mm.
Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
Measurements made through glass (window panes) can falsify
measurement results.
An energy-saving function switches the device off automatically.
Clean with a soft cloth. No water is allowed to penetrate the
housing.
Error codes:
Err10:
Replace the battery
Err11:
Data transfer error
Err14:
Calculation error
Err15:
Outside the measuring range
Err16:
Received signal too weak
Err18:
Tilt sensor calibration error
Information on maintenance and care:
Clean all components with a damp cloth and do not use cleaning
agents, abrasives and solvents. Remove the battery(ies) before sto-
ring for longer periods. Store the device in a clean and dry place.
Calibration:
The measuring device should be calibrated and tested on a regular
basis to ensure it is accurate and working properly. We recommend
the measuring device is calibrated every 1 - 2 years. If necessa-
ry, contact your distributor or the UMAREX-LASERLINER service
department.
Technical Data:
(Subject to technical changes without notice. 23W05)
Distance measurement:
Precision (typical)*:
Measurement range (inside)**: 0.05 m - 50 m
* measuring distance up to 10 m with strongly reflective target sur-
face and at room temperature. The measurement deviation may
increase by ± 0.2 mm/m for greater distances and under unfavoura-
ble measuring conditions such as strong sunlight or weakly reflecti-
ve target surfaces.
** at max. 5;000 lux
Angle measurement:
Measuring range:
Resolution:
Precision:
± 1.5 mm
± 90°
0.1°
0.1°