Installation instructions
The inflow pipe must be installed at a gradient of about 1%.
The rainwater inlet must be a straight length of tube with an inflow calming
section of at least 0.5 m in length. The LineAr 100 VA rainwater filter must
be positioned in the access shaft of rainwater storage tanks
in such a way that the filter insert can be easily removed with the lifting
handle for regular maintenance. It must be possible to lift out the insert
from ground level without needing to climb into the access shaft or rain-
water storage tank.
Before the filter is installed in an access shaft or rainwater storage tank,
the height differential inside the LineAr 100 VA rainwater filter and the pipe
gradient in the access shaft / rainwater storage tank must be taken into
account. The internal height difference between the invert levels is 52 mm.
To ensure the free flow of water through the LineAr 100 VA rainwater filter,
the nominal size of the soakaway/storm drain outlet pipe must not be
smaller than the nominal size of the rainwater inlet pipe.
If the installation conditions do not meet the described requirements, or
if the difference in invert levels makes use of the LineAr 100 VA rainwater
filter impossible, we recommend that you install the WISY downpipe filter
collector in the rainwater downpipe instead.
Installation
!
The filter housing must be installed on the horizontal, the filtered water
outlet must be aligned perpendicular (use a spirit level).
Before installation work commences, the filter insert must be removed
from the LineAr 100 VA rainwater filter housing and stored safely in a clean
place.
After the filter insert has been removed, the pipes can be connected to the
housing of the LineAr 100 VA rainwater filter.
Make sure that no stress is placed on the connecting pipes.
The rainwater inlet is designed as a socket (collar) for insertion of a DN
100 pipe.
The inflow pipe should be inserted by 45 mm (minimum 40 mm, maximum
50 mm) into the socket.
The storm drain connection of the LineAr 100 VA rainwater filter must be
connected to a socket.
The rainwater outlet DN 100 must be connected to a socket DN 100.
The LineAr 100 VA rainwater filter is correctly positioned when the rainwa-
ter outlet is aligned exactly perpendicular.
Once installation of the filter housing is complete, the filter insert can be
placed inside.
Important: Take care when placing the filter insert inside the housing
and make sure that it is correctly positioned.
When the installation work has been completed and the filter insert placed
inside the housing, the LineAr 100 VA rainwater filter must be tested for
proper functioning; the incoming water must flow as filtered water through
the calming inlet into the rainwater storage tank.
Warning notice:
!
The WISY LineAr 100 VA rainwater filter is not a closed system. In the
event of exceptionally heavy rainfall, a defect in the drainage pipes,
a blockage in the drainage system, etc., there is a risk that water will
escape from the LineAr 100 VA rainwater filter. We do not accept res-
ponsibility for any consequential damage.