B – Control panel
B1 – On/Off switch
B2 – On/Off switch indicator lamp
B3 – Operation mode selection button
B4 – Operation mode indicator lamps
B5 – RH setting button
B6 – LED display
B7 – Timer
III. PREPARATION FOR USE
Remove all the packing material and take out the appliance. Remove all possible adhesion
foils, stick–on labels or paper from the appliance. Place the appliance on a suitable flat and
dry surface. Leave free space for due ventilation. Vents in the appliance ensure air circulation
during ventilation and they must not be covered or blocked in another way. Make sure that
the power cord is not damaged and that it does not lead any sharp or hot surfaces. The
electric socket must be easily accessible so that the appliance can be easily disconnected
from power supply if danger appears.
INSTALLATION AND POSITION OF THE APPLIANCE
Place the appliance on a flat surface in a good ventilated room. Avoid direct sunshine,
observe minimum distance of 30 cm from back and side walls or other obstacles.
Observe the instruction provided in the Safety section.
RH indication levels (RH = Relative humidity)
The appliance shows 3 basic colours indicating RH level.
Blue
RH < 45%
Green
45 % ≤ RH ≤ 65 %
Red
RH > 65 %
Remarks related to the functioning of the appliance
– Functional principle of the appliance consists in circulation of air in the cooling circuit,
where condensation of air humidity and its drainage into the condensed water tank
occurs.
– Compressor dehumidifiers are most efficient at higher ambient temperatures (approx.
30 °C). The lower ambient temperature, the lower dehumidification efficiency.
In standard household, the appliance should be used at 22 - 25 °C or higher
temperatures. Therefore, it is advisable to combine drying with air heating in the event
of increased dehumidification requirements (e.g. using hot air fan, which will increase
the temperature and, at the same time, air circulation intensity).
– Optimum air humidity in summer ranges 40 - 55 %, in winter 45 - 60 %.
AUTOMATIC DEFROSTING „NO FROST"
The appliance has an automatic defrosting function which turns off the compressor during
operation and activates the highest fan speed for 10 minutes. Indicator lamp B2 will be
flashing in the defrosting mode. The following conditions are relevant for this function:
B8 – Timer indicator lamp
B9 – Fan speed selector button
B10 – Fans speed indicator lamp
B11 – Button lock
B12 – Button lock indicator lamp
B13 – Condensed water indicator lamp
C – Drain tube