Preparation
Type labels in different languages are included in the package. Stick the language label in your
language over the German language label on the countdown timer.
Connecting a device to the countdown timer
• Set the desired time on the countdown timer (see next chapter).
• Switch off the device that you want to connect to the countdown timer (provided it has an
on/off switch).
• Plug the device into the outlet of the countdown timer, inserting the plug all the way.
• Switch the device on.
• Depending on the position of the setting ring on the countdown timer, the connected device
is switched on. The device is switched off automatically after the set countdown time expires.
Should the timer stop earlier than expected, slowly turn the setting ring to the right
(clockwise) until the arrow " " inside the ring points to the position "OFF". The
countdown timer and the connected device are switched off.
Setting the countdown time
Turn the outer setting ring with the printed time division's clockwise (paying attention to the
arrows on the outer edge of the ring) until the arrow " " inside the ring indicates the desired
countdown time. The outlet as well as the connected device are switched on automatically.
Turn the setting ring only to the right (clockwise), it can be moved easily.
It is not possible to turn it anti-clockwise! Do not exert any force as this will destroy
the countdown timer and void the warranty!
The countdown timer only works when it is supplied with electricity, i.e. when it is connected to
an active mains socket.
Once the set countdown time has expired, the connected device as well as the countdown
timer are switched off. The arrow " " inside the ring points to the position "OFF".
If you wish to start a new countdown, proceed as described above.
Care and cleaning
Before cleaning the product, disconnect any device from the countdown timer. Disconnect then
the countdown timer from the power supply by pulling it out completely from the mains socket.
Never use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since these
could damage the housing or even impair operation.
Use a dry, lint-free cloth to clean the product.
Disposal
This symbol must appear on any electrical and electronic equipment placed on the
EU market. This symbol indicates that this device should not be disposed of as
unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back
of waste. Conrad provides the following return options free of charge (more details on our
website):
• in our Conrad offices
• at the Conrad collection points
• at the collection points of public waste management authorities or the collection points set up
by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in
countries outside of Germany.
Technical data
Operating voltage ......................... 230 V/AC, 50 Hz
Connection power ......................... Ohmic load: max. 3680 W (230 V/AC, 16 A)
Inductive load: max. 460 W (230 V/AC, 2 A)
Devices with mainly resistive load are, e.g., light bulbs, heaters, etc.
Powered devices with inductive load are, e.g., engines, control gears, conventional
transformers, energy-saving bulbs, etc.
Protection type .............................. IP20
Switch type ................................... Microswitch (single-pole)
Countdown time range ................. 1 - 60 minutes
Enhanced protection
against accidental contact ............ yes
Ambient conditions ....................... Temperature 0 °C to +55 °C, air humidity 0% to 85% rela-
tive, non-condensing
Dimensions ................................... 82 x 81 x 78 mm (L x W x H, including plug)
Weight .......................................... 130 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
*2522651_V2_0623_02_jh_mh_en

Werbung

loading