7.Cleaning and replacing lters
Product daily cleaning and maintenance
1. Make sure that the power cord is disconnected while the
appliance is cleaned and maintained.
2. Wipe the fuselage with a soft cloth that is moderately moist and
clean, and then dry with a dry cloth, please do not To wet the
machine directly with water, keep the machine dry during
cleaning to avoid causing electricity Source failure.
3. The lter must be replaced at least every 4 to 6 months.
4. Use a brush to clean the air inand of the machine.
5. If not in use for a long time, store the machine in a dry and
ventilated place.
8. Common faults and troubleshooting
methods
No.
Problems
Ensure the product adapter is properly connected to
the power supply .
Failed to turn on
1
Ensure the adapter is properly connected to the
the unit
machine.
Check that the adapter is disconnected from the
socket and connected to the power again.
Check that the power adapter output head is
The unit suddenly
disconnected from the machine power interface and
2
doesn't work
connect it.
Check if the machine is in standby mode and restart
the machine when it is in a xed state.
If the machine is in normal operation, check whether
the lter element packaging bag is removed.
No air ow in the
If the machine is normally used for a period of time,
3
air outlet
the lter element will absorb a lot of pollution.
The lter element shall be cleaned or replaced.
Check if any debris falling inside the puri er duct.
Check whether the lter element absorbs a large
4
Noise increases
number of pollutants, clean or replace the lter
element.
Not e ective
Please replace the lter screen, as it may have
removing smoke
5
reached the suction capacity.
No odor removal
You need to replace the new strainer.
function
Solution
06