1.The Pre- lter lters out abrasive substances as a defence for the
HEPA lter.
2.HEPA Filter eliminates 99.5% of pollutants as small as 0.3 µm or
larger pollen and dust mites and lters air pollution of PM 2.5.
6.How to operate the machine
1. First connect the DC plug of the switched power supply to the dc
socket of the machine, Then connect the AC plug to a power outlet.
2. Press the power button lightly, the machine starts to work, the blue
running indicator light and decorative light are on at the same time,
and the fan runs at low speed by default. The timing is always
running, and the air ow will be discharged from the air outlet.
3. After power on, the fan defaults to low speed, press the fan button
once for medium speed, press again for high speed, press again for
low speed, and the corresponding indicator light is on.
4. After booting, the time runs by default. Press the timer button for 2
hours customization, 2 times for 4 hours, 3 times for 8 hours, 4 times
for 10 hours, 5 times 12 hours customization, and the corresponding
indicator lights up, press again It returns to running all the time, and
the indicator light goes out.
5. After power on, the decorative light is on by default. If you need to
turn it o , Press the button the rst time, the blue LED circle light on
the panel will be o , and the blue LED night light will be on. Press
the button the second time, the blue LED circle light on the panel
05
will go out, and the blue LED night light will go out. Press the button
the third time, the blue LED circle light on the panel turn on, and the
blue LED night lights go out. Press the button the fourth time, and the
blue LED circle light on the panel will be turned on and the blue LED
night light will be lit.
6.When the service life of the HEPA lter reaches 2500 hours, the
HEPA reset indicator lights up and ashes at a frequency of "0.5
seconds on and 0.5 seconds o "; remind the user to replace the
HEPA lter, and restart it when the HEPA lter is replaced. The HEPA
reset indicator lights up, and it ashes at a frequency of "0.5 seconds
on and 0.5 seconds o ". At this time, press and hold the "Night light"
button for 3 seconds, the HEPA reset indicator turns o , and the time
set by the HEPA lter restarts from zero.
7. Please turn o the machine before replacing the lter, unscrew the
knob from the bottom of the machine, open the bottom cover, take
out the lter , put the new lter back to the correct position in the
machine, and screw on the bottom cover.
8.If you need to continue puri cation, just restart the machine.