Balluff MICROmote BAE Serie Bedienungsanleitung Seite 2

Optoelektronische sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Photoelectric sensors
916403_AA_EN · B23
Subject to modification. Replaces L14.
MICROmote®-amplifiers BAE
Analog amplifiers for sensor heads BOH
Order code
Analog Amplifiers Premium
BAE00RA
BAE SA-OH-038-IC-S92G
BAE00R9
BAE SA-OH-038-IC-S75G-SA3
www.balluff.com
Operation
The different operation modes and parameters are set by a
4-position slide-switch and a JOG-switch with push-button
functionality.
Switch
Inscription
Function
JOG-switch
+
increment
push-button
(confirmation of selection)
-
decrement
slide-switch
* OUT
inoperable
OPT
- operation modes
TEA
- teach-modes
RUN
- signal strength display;
- selected parameters:
+ = increase amplification
- = decrease amplification
- external TEACH
Menu navigation
Slide-switch
JOG-Switch
selection of
selection with +/-
main menu
confirm with
level 0
level 1
OPT
Option
TEA
Teach
RUN
0....999
Operation
+ RemoteTeach
The actual setting is permanently lit up.
Flashing display means: indicated value can be selected. Confirm by pushing JOG-switch.
Technical data
Max. frequency response
Power supply indicator
Operating voltage
Output signal
Current consumption
Weight
Casing material
Operating temperature
Protection class
Caution!
Sensor and amplifier are only intended
for object detection. Do not use amplifier
and sensor for personnel safety applica-
tions!
Push
JOG-switch
slide-switch
* Slide-switch OUT is omitted in the version with
3 positions.
JOG-Switch
selection with +/-
confirm with
level 2
Parameter
n o
lock
Y E S
Turn display
Display
n o
off
Y E S
Default
n o
Y E S
factory setting
fully automatic teach
8...999
Potentiometer
Actual amplification (0,8...99,9%)
+
Signal
0...999
+ gradual increase
strength
Actual amplification (0,8...99,9%)
-
0...999
+ gradual decrease
Connection
1kHz
Sensor
LED green (PWR)
M8 connector, 3pins
15 ... 30VDC (max.)
4 - 20mA
(RLmax = 500 Ohm)
45mA / 180mA
In- /Output
65g
ABS
2 m PVC-cable, 5 x 0,14 mm
-10°C bis +55°C
IP54
M12 connector, 5pins
M8 connector, 4pins
Mount
Put device onto DIN rail clip as shown.
Then, connect sensor cable.
Teach instruction
Push JOG-switch to start teach
procedure.
Push JOG-switch in + or -
direction
Remote-Teach
The amplification level of the amplifier can be
adjusted remotely through the PLC via the
teach-input (pink/grey).
(N.B.: only in RUN mode!).
The remote teach procedure is
actuated by two pulses from the
PLC to the amplifier. The duration
of the second pulse defines the
storage of the determined am-
plifcation level.
1.) X = 2,0 - 4,5s:
2.) X = 0,1 - 1,5s:
Wiring
4
1 + emitter
4 GND/shielding
3
1
3 + receiver
2
brown
+ VDC
white
analog GND
blue
- GND
black
analog +
pink
remote teach
4
3
1 (brown)
+ VDC
2 (white)
analog GND
3 (blue)
- GND
5
4 (black)
analog +
5 (grey)
remote teach
1
2
1 (brown)
+ VDC
4
2
2 (white)
remote teach
3 (blue)
- GND
3
1
4 (black)
analog +
Dismount
First unplug sensor cable connector.
Then take amplifier off the DIN rail clip as shown.
Manipulation
Action
Teach procedure determines
max. possible amplification
to use the full range upto
saturation level.
Manual adaptation of amplifi-
cation (0,8%...99,9%)
from minimum to saturation
Required voltages
Input voltage
Input voltage
Input current:
1
0,1 - 30 s
2,0 - 4,5 s
0
( teach duration)
Permanent storage (100.000 times max.)
Non permanent storage (until next power cutoff)
BAE SA-OH-038-IC-..
VDC
brown
Analog +
black
R
L
Analog GND
white
GND
blue
Remote teach
pink / grey
Notice
Teach procedure terminates
automatically.
PNP
NPN
Signal „1":
>9V
<3V
Signal „0":
<5V
>6V
<3mA
<3mA
signal from PLC
X

Werbung

loading

Diese Anleitung auch für:

Micromote bae sa-oh-038-ic-s92gMicromote bae sa-oh-038-ic-s75g-sa3Bae00raBae00r9