Herunterladen Diese Seite drucken

axing premium-line BVS 12-69N Betriebsanleitung Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Field of application:
The devices are suited only for amplifying radio and television signals in the
house! If the device is used for other purposes, no warranty is given!
The illustration shows application examples for the distribution in star (1) and
tree structure (2).
(1)
(2)
Equipotential bonding and Mounting:
To avoid dangerous overvoltages (attention: risk of fire/death), the
devices must be connected to the equipotential bonding according to
EN 60728-11.
4
Use the equipotential bonding connection attached to the device
(3).
4
To connect the outer conductor of the coaxial cable to the
equipotential bonding, use e.g. earth connection blocks CFA 7-01
at the input and output of the amplifier.
4
Use the mounting screws included in the delivery and the
mounting holes of the devices (4).
RF Installation:
4
Connect the input of the amplifier to the interconnection point.
Connect the output of the amplifier to the antenna sockets or the
taps used.
4
Use a highly shielded coaxial cable with an F connector. Suitable
cables and connectors can be found in the current AXING
catalogue or under www.axing.com.
3
4
Input
Output
5
6
7
Level Adjustment:
With the controllers (5) and (6) you can control the equalization and
attenuation of the forward path, with the controller (7) you can control
the attenuation of the return path.
4

Werbung

loading

Diese Anleitung auch für:

Premium-line bvs 13-69n