Herunterladen Diese Seite drucken

axing premium-line BVS 12-69N Betriebsanleitung Seite 3

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Safety advices:
4
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
4
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
4
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is
a risk of mortal injury for which we cannot be held liable.
4
Providing that a serviceable fuse exists, the power cord must be pulled
out before changing the fuse. Defective fuses may only be replaced
with standard compliant fuses that have the same nominal value.
4
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
4
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. Power feeding cables as well as feeder lines may not
be damaged or clamped by objects of any kind. To prevent damage to
your equipment and to avoid possible peripheral damages, the devices
foreseen for wall mounting may only be installed on a flat surface.
4
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible
damage to the equipment as well as a risk of fire caused by
overheating. Absolutely avoid that cables come near any source of heat
(e.g. radioators, other electrical devices, chimney, etc.).
State of the art
201
6-12-13 Technical changes, design modifications,
errors and misprints are subject to change without prior notice.
Technical data:
BVS 12-69N
KDG classification
B (1.2)
Downstream
Frequency range
85...1006 MHz
Gain
17...20 dB
1
Output level [CSO/CTB ]
100 dBµV/98 dBµV
Noise figure
Adjustable attenuator
Equalizer
Upstream
Frequency range
5...65 MHz
Gain
17...20 dB
Attenuator
Common
Power supply
230 V~/50 Hz
Power consumption
Dimensions appr.
192 × 89 × 40 mm
1
CENELEC Raster 41 ch. 60 dB IMA
2
CSO/CTB @ 3dB slope, 100 dBµV
2
CSO/CTB @ flat 0dB slope, 98 dBµV
Manufacturer
EWR contact adress
AXING AG
Bechler GmbH
Gewerbehaus Moskau
Am Rebberg 44
8262 Ramsen
78239 Rielasingen
BVS 13-69N
B (3.2)
27...30 dB
2
7 dB
20 dB
BVS 12-69N | 13-69N
18 dB
premium-line
25...28 dB
CATV Amplifiers
20 dB
Operation Instructions
6 W

Werbung

loading

Diese Anleitung auch für:

Premium-line bvs 13-69n