QUICK GUIDE
Installing the mains power cable on the Ultronic
INSTALLATION
1. General information
1.1
Relevant documents
Operating and installation instructions
Ultronic hand dryer, part number 296654
2. Appliance description
2.1
Standard delivery
The following are delivered with the product:
- Power cable
- Cable gland
- Discharge resistor
- 4 wall spacers
3. Installing the power cable
WARNING Electrocution
Ensure that the appliance is isolated from the mains
power supply during installation.
Note
In the event of damage to the power cable or dis-
charge resistor, these must be replaced by a qualified
contractor using our original spare parts.
3.1
Removing the casing cover
f Observe the information in the operating and installation
f
instructions for the hand dryer (see chapter "Installation").
3.2 Installing the cable gland
1 Terminal strip
2 Cable entry
317232-38386-8974
f Push the cable gland into the cable entry from inside the
f
appliance.
f Ensure the cable gland clicks into place inside the cable
f
entry.
f Route the power cable through the cable gland from the
f
back of the appliance.
Note
The power cable sleeve must extend 5–10 mm into the
appliance from the cable gland.
1
2
f Tighten the lock nut (left-hand thread) hand-tight.
f
f Tighten the cable gland (right-hand thread) by the cap nut
f
using pliers.
As you tighten the cap nut, the lock nut will also tighten.
2.
1.
| 3