Herunterladen Diese Seite drucken

Casa Fan AERODYNAMIX 132 Montageanleitung Und Bedienungsanleitung Seite 14

Deckenventilator

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
General
- The voltage details on the nameplate are to conform with the available mains voltage.
- The building mains must be earthed!
- Only operate the unit when completely assembled!
Important
- It is recommended that a specialist electrician is used for making the electrical connection
to this fan.
Safety instructions
Before accessing the connection, all current carrying conductors are to be isolated.
The mains connections to which you are connected is to comply with current specifications.
The fixed wire connection is to be provided with a multi-pole isolator with contact gaps of at
least 3 mm. We recommend that the connection be made by a qualified electrician.
The construction of the holder and/or the output box is to be able to bear the weight of the
fan when being moved, ie, about 15 kg minimum. Chose a secure, safe location. None of the fan
blades are to be less than 2.30 m from the ground. The fan is to be correctly earthed.
Before first using the setup, all electrical connections are to be checked in order to prevent any
fall, fire or electric shock.
Installing your ceiling fan
Ascertain that a junction box is available at the intended mounting point.
If this not the case, then fix the mounting plate directly to the ceiling using wood screws having
a diameter of 6 mm and, if necessary, 8 mm diameter concrete anchors or special plugs suitable
for plaster boards.
Proceed as per fig. 1 - 7 shown on page 4 - 9
- Unpack the ceiling fan and check the contents. All the parts shown in the drawing are to be
present.
- Assemble the mounting plate using the screws and washers to the ceiling outlet.
In order to assure a safe operation of your fan, make sure that the mounting plate is firmly
seated and is level.
-The attached part is to be vertical.
- Disconnect the electricity before working on the electrics.
- Make the electrical connection to your fan as per Figure fig. 3 on page 5.
- Please ensure that all cables are correctly connected. Do not pinch any wires or damage the
cable insulation!
- Fix the blades to the motor using the bolts.
- If you are installing several fans, make sure that the various blades are not mixed up,
- The blades are grouped according to weight, in order to avoid vibration.
- After finishing assembling the fan, make sure that all connections are in order and that all nuts
and bolts are tightened.
Operating your fan
Make sure that the assembly has been completely finished.
For controlling your fan only use the included remote control. Never use a dimmer or a phase
angle or phase inverse angle controller.
14

Werbung

loading