5) Overwriting the master transmitter

1. Turn off the power supply to the VC320 and switch back on after 5 seconds.
The VC320 goes into programming mode for 3 minutes.
Note
To ensure that the new master transmitter is programmed in the desired
VC320 only, all other receivers which are connected to the same power
supply must be deactivated from the programming mode.
To do so, after switching back on the power supply, execute a control or
stop command using the transmitter for the given receivers.
2. Now press the programming button of the new master transmitter for 10 sec-
onds.
The shutter will "nod" to confirm.
The new master transmitter has been programmed and the old master transmit-
ter deleted.
14

6) Programming switching times

Note
This function is only available with the transmitters MemoControl
MC441 and MC411, which can be found in the Centronic range from
Becker.
The VC320 can store switching times for one UP and DOWN command.
If the sliding switch is set to auto "", this command is repeated every 24
hours.
The / position for the sliding switch is unimportant when programming the
switching time. All previously stored switching times are overwritten accord-
ingly.
1. If necessary, adjust your roller shutter into the final position opposite to the
desired running direction.
2. Wait until the time at which the automatic control command is to be execut-
ed.
3. At the desired time, press the desired direction key and hold down until the
roller shutter drive stops briefly after approximately 6 seconds and then
moves into the final position.
4. Release the direction key.
The VC320 will automatically store the current time for this control command.