Information concerning airborne noise and vibration
The measured values were determined according to
EN62841 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 96 dB (A)
Measured A-weighted sound pressure level: 85 dB (A)
Uncertainty K: 3 dB (A).
Wear hearing protection.
Vibration total values (triax vector sum) determined
according to EN62841.
Vibration emission value
Uncertainty K = 1.5 m/s
2
TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult your
dealer or the HiKOKI Authorized Service Center.
1. Power tool
Symptom
Does not move
Suddenly stopped
Switch can't be pulled
Cannot install battery
a
h, B = 2.5 m/s
2
Possible cause
No battery remaining.
Battery is not properly installed.
Battery was installed with the switch pulled.
Overload protection circuit activated.
The material being mixed is viscous.
Heat protection circuit activated due to
overheating of the battery or the tool itself.
Lock-off button is pushed in
Attempting to install battery other than type
specifi ed.
The declared vibration total value and the declared noise
emission value have been measured in accordance with a
standard test method and may be used for comparing one
tool with another.
They may also be used in a preliminary assessment of
exposure.
WARNING
○ The vibration and noise emission during actual use
of the power tool can diff er from the declared total
value depending on the ways in which the tool is used
especially what kind of workpiece is processed; and
○ Identify safety measures to protect the operator that
are based on an estimation of exposure in the actual
conditions of use (taking account of all parts of the
operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the
trigger time).
NOTE
Due to HiKOKI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
Charge the battery.
Push battery in until a click is heard.
Due to activation of the safety feature.
Release the switch once and pull it again so
the tool moves.
Remove cause of overload.
Switch from High speed to Low speed.
Allow battery and tool to fully cool down.
Release the Lock-off button.
Use Multi Volt type battery.
14
Remedy