Herunterladen Diese Seite drucken

X-10 REX-10 Betriebsanleitung Seite 18

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Secured Modes:
3) Secured mode 1 (unit set to RUN, and ARMED LED off, disarmed by security remote DISARM, or
manually):
Console works as X10 PLC Transceiver for dusk/dawn detection from PIR to control e.g. a
light on PIR X10 HOUSE CODE/X10 UNIT CODE+1 on(dusk)/off(dawn).
Console works as standard RF/PLC transceiver. All X10 UNIT Codes/commands to the set X10
HOUSE CODE are passed on to the power line.
When sending X10 PLC command on the correct X10 HOUSE CODE/X10 UNIT CODE
combination, it starts/stops the barking.
Console works as X10 PLC Transceiver for security lights, in case of security lights light on/of
button KR18/KR10/21, the console sends X10 HOUSE CODE/X10 UNIT CODE+1 on/off. SH600
does not have this button
Console responds to PANIC button of assigned security remotes; Panic RF will trip the
console for 30 seconds.
4) Secured mode 2 (unit set to RUN, and ARMED LED lit, armed by security remote ARM, or
manually):
Idem as Secured Mode 1 +
With RF the unit does respond and is tripped to the set X10 HOUSE CODE/X10 UNIT CODE. So
default X10 HOUSE CODE=A/X10 UNIT CODE=1, and this can be set by changing the code
wheel for the X10 HOUSE CODE, and sliding the switch to INSTALL and send the respective
X10 UNIT CODE via any X10 standard HA RF code.
Trigger Periods:
The trigger period operates as follows:
When triggered, the unit will immediately start barking
5 seconds after a trigger, the unit code (X10 UNIT CODE) + On power line signal will be sent
4 minutes later, the unit will cease barking and X10 UNIT CODE + Off power line signal will be
sent
If the unit is triggered and then receives another trigger a minute later, the response will be as
follows:
When initially triggered, the unit will immediately start barking
5 seconds after a trigger, the unit code (X10 UNIT CODE) + On power line signal will be sent
When the new trigger is received (assume after a minute) the alarm timer will be reset to 4
minutes
5 seconds after the new trigger, the unit code (X10 UNIT CODE) + On power line signal will
be sent
4 minutes after the new trigger, the unit will cease barking and X10 UNIT CODE + Off power
line signal will be sent
So, in this example, the barking time has been extended by one minute as a result of the new
trigger.
In case of PANIC code:
Panic
Panic
Panic
Sensor
Sensor
Panic
Sensor
Sensor
Panic
Panic
Panic
Sensor
Sensor
Panic
Sensor
Sensor
30 seconds - the second panic does not retrigger
max: 30 seconds plus 4 minutes for the alarm
4 minutes, the panic is ignored
max: 7:59 minutes if the second alarm was received at 3:59
max: 60 seconds - the second panic DOES retrigger
max: 30 seconds plus 4 minutes for the alarm
4 minutes, the panic is ignored
max: 7:59 minutes if the second alarm was received at 3:59

Werbung

loading