Low battery: If the batteries are empty, you must charge them with the solar panel for at least 4-8
hours in direct sunlight.
Low Water level: If there is not enough water in the reservoir, the irrigation will switch off, in this case
fill up the water level in the reservoir to ensure irrigation.
Cycle Function: To ensure that watering is as water-saving and gentle on plants as possible, the
irrigation system has been optimised for night-time water delivery.
After setting the pump runtime once, the pump works automatically in the predefined cycle.

5. CLEANING AND MAINTENANCE

The irrigation unit should be cleaned at regular intervals with a soft cloth. It is recommended to clean
the solar panel regularly to ensure optimal conversion of solar energy into direct current.
Please note:
The battery pack has to be exchanged at the latest every 12-18 months! The Solar modu-
le should only be cleaned with soft tissue and proprietary glass cleaning solution.

6. RECOGNISING AND REPAIRING OF MISTAKES

Problem

Possible cause

No electricity
Pump does
not start
Pumpe defekt /
Solar- Panel defekt
Low battery
Pump impeller or filter housing
dirty
Pump runs
Pump has sucked in air
but no
(Attention! Avoid dry running)
water is
Hoses or hose connections have a leak Check hoses or hose connections
encouraged
Pump has a leak
Intake openings dirty

7. SECURITY TIPS

z Obey absolutely valid regulations on the electrical security
z Never run pump dry. Test wells for enough flowing water (dry run danger)
z Pumping inflammable, as well as all other aggressive liquids is prohibited
z Observe water temperature of max. 35°C
z The mains plug must be disconnected before carrying out any work on the irrigation system
z During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
z All solar panels are very sensitive, protect it before all against extremal mechanical influences (shock, vibration, etc.)
The manufacturer explains:
z To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard
to the instruction in this book.
z To reject every responsibility for the damages which original from the improper use
Solution
1. Check electr. connections
2. Check batteries
3. Align solar panel so that it receives direct
sunlight
Replace pump or solar panel.
For fault location: Check the solar panel to see
if the specified voltage is being supplied. Check
whether the specified voltage is provided. Operate
the pump with an external battery.
Fully recharge the battery (4-8 hours)
Dismantle and clean the pump and the housing
(using water and a soft brush).
Switch off the pump briefly and switch it on
again. (Restart)
Check if there is water in the pump housing
Clean intake openings