1
SIDE terminal is used for connecting any external device that operates double gate.
2
COM terminal is COMMON used for connecting the "ground" of external devices.
3
SIDE terminal is used for connecting any external device that operates single gate.
4
Swipe Card terminal is used for connecting any external devices that will operate to
open the gate.
5
COM terminal is COMMON used for connecting the "ground" of external devices.
6
Infrared terminal is used for connecting photo electric sensor.
7
12V DC output is used for connecting photo electric sensor (Continuous output cur-
rent <=200mA).
8
24V battery output is used for connecting the back up battery +.
9
24V battery output is used for connecting the back up battery -.
10
24V DC output is used for connecting external device. (such as photo electric sensor,
max current output 1A).
11
GND is used for connecting the "ground" of external devices.
12
24V DC lamp output is used for connecting flash light +.
13
24V DC lamp output is used for connecting flash light -.
14
24V DC lock output—the NF terminal which used for connecting the electric lock.
Control board wiring diagram
25
26
27
28
29
8 9 10 11 12 13 14 15 16 17 18
19
20
21
15
COM is COMMON used for connecting the "ground" of lock.
16
24V DC lock output—the NA terminal which used for
connecting the magnetic lock.
17
24V DC alarm output.
18
24V DC alarm output.
19
Motor1 terminal is used for connecting the motor 1 installed
on the gate that opens later and close first. This terminal
20
connect 1st red wire (from your left hand side to right hand
side).
21
Motor2 Delay terminal is used for connecting the motor 2
installed on the gate that opens first and close later. This ter-
22
minal connect 1st blue wire ( from your left hand side to right
hand side). NOTE! If for single gate, the gate motor just can
connect the Motor2 Delay terminal.
23
AC24V input is used for connecting the transformer.
24
AC24V input is used for connecting the transformer.
25
Digital display is used for showing you the setting data.
26
INC+ is used for figure increase when setting the data.
27
FUN is used for recorde the data.
28
DEC- is used for figure decrease when setting the data.
29
Learning button is used for program/remove remote.