Assembly instruction
Optical Connection
1. Clean the output fibre optical connector and check the
optical power using a suitable optical power meter.
Optical power at the output of the OL17 is +7dBm ±0.5dB.
2. Clean the optical connecter and make a connection to
the optical output of the OL17, ensuring the keyway is
aligned.
3. Important - The gel muft supplied should be clipped
around the FC/PC connector to ensure weather protection.
Performance / operational lifetime may be affected if
the gel muft not fitted.

Power Connections

1. The OL17 can be directly powered at F connector
power input using a 20V PSU with the DC-jack to F adapter.
2. The mains adapter is the disconnect device for the unit.
Please ensure it is easily accessible.
3. LED on the OL17 indicates correct powering of the unit.
The LED should be constantly green.
4. Maximum current draw 350mA (excluding current on
connected inputs).