M600NH / M700 / M900 / M900-CC / M1200-CC
The following inspection must be performed before the start of each work session or after every four hours of use,
whichever is fi rst. Please consult the service section for detailed guidance. If any fault is discovered, the machine
must not be used until the fault is rectifi ed.
1. Thoroughly inspect the machine for signs of damage.
2. Check hoses, fi ller openings, drain plugs and any other areas for signs of leakage. Fix any leaks before operating.
3. Check the engine oil level and top up if required. Use proper engine oil with the proper viscosity (SAE 10W-30
is recommended).
4. Check the engine fuel level and top up as necessary. Use clean fuel. The use of contaminated fuel may damage
the fuel system.
5. Check for oil and fuel leaks.
Improper operation can be hazardous. Read and understand this section before you start the
machine.
CAUTION
HONDA GX160 & GX200, GX270
1. Open the petrol tap by moving the fuel ON/OFF lever fully
to the right.
2. If starting the engine from cold, set the choke ON by moving
the choke lever fully to the left. If restarting a warm engine,
the choke is usually not required, however, if the engine
has cooled to a degree, partial choke may be required.
3. Turn the engine ON / OFF switch clockwise to the 'I' position.
4. Set the throttle to the idle position by moving the throttle
lever fully to the right. Do not start the engine on full
throttle.
5. Taking a fi rm hold of the control handle and set the
centrifugal switch to ON if not already, grasp the recoil
starter handle with the other. Pull the recoil starter until
engine resistance is felt, then let starter return.
6. Taking care not to pull the starter's rope fully out, pull the
starter handle briskly.
7. Repeat until the engine fi res.
8. Once the engine fi res gradually set the choke lever to the OFF position by moving it to the right.
9. If the engine fails to fi re after several attempts, follow the troubleshooting guide on page 12.
10. To stop the engine, set the throttle to idle and release the control switch safety switch. Alternatively turn the
engine ON/OFF switch anti-clockwise to the 'O' position.
11. Turn the petrol off .

Pre-start checks