PROTECTION FEATURE

Inverter is equipped with numerous protection features to ensure safe
operations�
Input Low Voltage Protection
When battery voltage is below 10�5 ± 0�5 V, Buzzer sound 2 times, which
indicates DC power supply voltage is descending and batteries need to
recharge�
When input voltage reach 10 ± 0�5 V, Buzzer sound 3 times and red light
turn on� AC output will be automatically shut off�
Input Over Voltage Protection
When input voltage reach 16±0�5V, Buzzer sound 4 times and red light
turn on, the AC output will be automatically shut off�

Short Circuit Protection

When short circuits occur, Buzzer sound 11 times and red light turn on,
output will be shut off�

Overload Protection

When overload occur, Buzzer constantly sound and red light turn on,
output will be shut off�
Reverse polarity protection: Fuse or MOSFET
Via Fuse: When battery terminals are reverse connected, fuse will be
burned to protect appliance�
Via MOSFET (Optional): When battery terminals are reverse connected,
the inverter won't work until correct connect�
Over Temperature Protection
When heat sink temperature exceed 45 °C, the inner cooling fan will
automatically turn on to cool the inverter�
!
WHEN INNER TEMPERATURE EXCEED 75°C, BUZZER SOUND 5 TIMES
AND RED LIGHT TURN ON, AC OUTPUT WILL AUTOMATICALLY SHUT OFF.

MAINTENANCE

To keep your inverter operating properly, there is very little maintenance
required� You should clean the exterior periodically with a dry cloth to
prevent accumulation of dust and dirt� At the same time, tighten the
screws on the DC input terminals�