COOLING
It is recommended to start the unit early on hot days, thus avoiding heating up of the room.
This unit has a self-evaporation function for condensation water, so that it is normally not necessary to empty the water tank in cooling mode. The drainage hose need
not be connected. Please make sure that the outlet is closed with the rubber cap during operation.
This does not apply in the case of high air humidity. If the unit operates in cooling mode for a longer period and especially at a time of year with high air humidity, the
condensation tank may be full. The control lamp will remind you to empty the water. Refer to error message E4. In such a case, empty the water tank via the condensation
water outlet. If continuous high air humidity is likely, it is recommended to drain the condensation continuously via the drainage hose.

COOLING IN INDOOR OPERATION

The unit stands in the room to be cooled. Connect the air hose and the air outlet grid to the unit as displayed in the
illustration; the air hose connection piece and air outlet grid need to be exchanged.
COOLING
Indoor air conditioner
COLD AIR OUTLET
The warm extract air must be emitted from the room via the air hose. This can be executed e.g. via a tilted window, a door or wall aperture. Make sure that no warmout-
side air can enter the room. For effective cooling, we recommend our selection of various accessories which reduce or prevent entry of warm air into the room.
Place the function to "COOLING". Set the target temperature using the temperature control. The settable temperature range is between 17 and 30 degrees target tempe-
rature. The unit must only be used in an ambient temperature of maximum 32°C. – standard version (45°C – tropic version)
Note: After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for three minutes. Cooling effect may require
a further 10 minutes. Further information is available under the item, "Troubleshooting".

COOLING IN OUTDOOR OPERATION

The unit can work as an efficient spot cooler cooling room locally. Connect the outlet cool air hose up to 5 m in length and direct it to the desired area. Hot air can be
blown into another room or discharged outside the room using a standard hot air outlet hose.