Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Basic Data - SCHUNK SLD Montage- Und Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical data

Tab.: Mechanical operating data
SLD max. stroke [mm]
11
5500
12
5440
13
5330
14
5190
21
5470
22
5440
23
5330
24
5190
Tab.: Electrical operating data
SLD
Max. idle current
[A eff]
11
2.2
12
3.6
13
5.1
14
6.7
21
4.1
22
6.5
23
9.6
24
12.5
Tab.: Pneumatic operating data
Pressure medium
Compressed air, compressed air quality
according to ISO 8573‐1:2010 [7:4:4]
Tab.: Ambient conditions
Min. ambient
temperature [°C]
temperature [°C]
5
Warranty
96
3 Technical data

3.1 Basic data

Rated force [N]
Maximum force [N] Repeatability [mm] Weight [kg] *
165
265
375
495
285
450
665
865
* Slide/motor
Max. current
[A]
6
12
18
24
12
24
36
48
Max. ambient
Surface tempe-
rature max. [°C]
40
Warranty duration [months]
or maximum performance [km]
or maximum cycles [piece]
More technical data is included in the catalog data sheet.
Whichever is the latest version.
300
600
900
1200
600
1200
1800
2400
Winding resistance at
25°C Z [Ohm]
7.2
3.8
2.4
1.9
3.14
1.57
1.04
0.80
Compressed air [bar]
IP rating
70
00
01.00 | SLD | Assembly and operating manual | de en | GAS425704
0.01
3.75
0.01
6.82
0.01
7.4
0.01
9.2
0.01
6.78
0.01
8.38
0.01
12.2
0.01
16.5
Max. intermediate
circuit voltage [V]
900
900
900
900
900
900
900
900
5 - 7
Noise emission
[dB(A)]
≤70
24
20.000
50 million