Specifications
Operating voltage: 12 V AC
Operating current: max. 140 mA
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Dimensions (mm) W x H x D:
99 x 99 x 27
Operation
Every button actuation is acknowl­
edged by a signal tone, incorrect
inputs are signalled by a multiple
tone.
Call via code
1–8-digit call numbers are possible
(1–9999 9999). Enter the required
call number and press the button
with the bellsymbol.
Example:
Krause
Schmitt
Initiate control functions:
1–8-digit code possible
(1–9999 9999).
Enter the code,
press the F button.
Cancel button "C"
Entries can be cancelled at any time
using the C button.
Door release function using
thekey button
If required it is possible, for example
at certain times of day, for the door
to be opened directly by pressing the
key button without entering a code.
This function can only be used
together with an EC 602-... easikey
controller.