Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning, Care & Maintenance; Technical Specifications - Polar CF750 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
EN
Cleaning, Care & Maintenance
Always switch off and disconnect the power supply before cleaning.
Warm, soapy water is recommended for cleaning. Cleaning agents may leave harmful residues.
Periodically clean the bottom of the cooler compartment to remove any build-up of condensation.
Condensation and ice will form with frequent and prolonged opening of the doors.
Operating outside of the recommend temperature range and placing next to a heat source will also
increase the amount of ice and internal/external condensation. If external condensation occurs wipe the
surface down with a cloth.
Excessive ice will result in longer running times that will increase energy consumption and increase the
deterioration of components.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is not
working
Appliance is noisy or
works intermittently
Cooler cabinet is not
cold enough
The light does not work
Doors will not close
properly

Technical Specifications

Note: Due to our continuing program of research and development, the specifications herein may be
subject to change without notice.
Model
Voltage
CF750
220-240V
50Hz
6
CF750_ML_A5_v8_20230512.indb 6
CF750_ML_A5_v8_20230512.indb 6
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Appliance is not level
Temperature set incorrectly
External environment may require
colder temperature
The door is opened too often
Door seal is worn
Bulb has blown
Light switch set to Off
Cooler is not level
Door has been reversed and not
properly fitted
Shelves are out of position
Door seal is dirty
Power
Current
Refrigerant
85W
0.55A
R600a
Solution
Check unit plugged in correctly and switched
on
Replace Plug or lead
Replace the fuse
Check mains power supply
Adjust the feet to level the appliance
Check temperature and reset if necessary
Check temperature and reset if necessary
Only open when necessary
Consult a qualified technician
Replace bulb
Set light switch to On
Adjust the feet
See "Reversing the Door"
Check all shelves are properly inserted
Wipe clean with a damp cloth
Temp.
Dimensions
Range
H x W x D mm
1-12°C
825 x 430 x 480
Weight
(kg)
26