1.0 GENERAL
i
The DV-12K is a time controlled relay box with
which a maximum of 2 x 600 watt fittings or
2 x 400 watt fittings can be switched. Next to
this, the DV-12K has an outlet for a heater.

1.1 TECHNICAL DATA

Dimensions
Required voltage
Max. Output
Max. output heater
Isolation level
1.2 REQUIRED (ACTIVE) VOLTAGE DV-12K
To connect the DV-12K you will preferably need
a 'clean' group of at least 6 Amp. A 'clean' group
means that this group will only be used by the
by the DV-12K. If you do not have a(n) (extra)
'clean' group we advise you to have the DV-12K
installed by a certified installer.
The DV-12K has a 6 Amp thermal fuse.
This fuse turns off the DV-12K automatically in
case of an overload and / or a short circuit.
1.3 THE INSTALLATION OF THE DV-12K
At the back of the DV-12K there are 2 mounting
brackets. This allows you to mount the DV-12K
onto a (flat) surface.
CAUTION!
The analogue timer is a sensitive part of the
DV-12K, and is not resistant to hard shocks.
DV-12K Binnenwerk PMS.indd 5
Manual DV‑12K
• Place the DV-12K close to your 'clean' group.
• Install, if needed, a grounded outlet onto your
• Plug the cord into the outlet of your 'clean'
• Your DV-12K is now connected to the mains
: 110 x 210 x 70mm.
: 230 Vac / 50Hz.
1.4 CONNECTING EQUIPMENT TO THE DV-12K
: 6 Amperes.
: 6 Amp.
You can connect 2 x 600 watt or 2 x 400 watt
: IP-44
fittings to your DV-12K.
In steps 1.2 and 1.3 you have;
• Connected your DV-12K to a 'clean' group,
• Mounted it onto a flat surface,
• Connected it to the mains voltage.
Now the electrical ballasts (fittings) will have
to be connected to the DV-12K. Please read the
installation manual carefully before you connect
the electrical ballasts, in order to connect them
properly.
If the electrical ballasts have been properly
connected there will be a 230V cord on each
of the electrical ballasts. Plug both cords of
the electrical ballasts into the power outlets
(sockets) on the side of the DV-12K. You now
have connected 2 electrical ballasts to the DV-
12K.
1.5 THE HEATER OUTLET
At the front of the DV-12K you will find a (green)
built-in power outlet (socket) for the electrical
heater of max. 6 Amp. This is where you can
place your heater.
At the bottom of the DV-12K you will find a
grounded (230v.) connection cord
'clean' group.
group.
voltage.
7