14
Maintenance and service
Especially for UK:
After servicing, complete the relevant Service Interval Record
section of the Benchmark Checklist located on the backpages of this
document.
NOTICE
Maintenance MUST be done by an authorised installer or
service agent.
We recommend performing maintenance at least once a
year. However, applicable legislation might require shorter
maintenance intervals.
14.1
Maintenance safety precautions
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
NOTICE: Risk of electrostatic discharge
Before performing any maintenance or service work, touch
a metal part of the unit in order to eliminate static electricity
and to protect the PCB.
14.1.1
Opening the gas boiler
See "9.2.1 To open the gas boiler" [ 4 15].
14.2
To disassemble the gas boiler
1 Turn off the appliance.
2 Turn off the main power supply of the appliance.
3 Close the gas tap.
4 Remove the front panel.
5 Wait until the appliance has cooled down.
6 Unscrew the coupling nut at the base of the flue pipe by turning
counterclockwise.
7 Slide the flue pipe upwards by turning it clockwise until the
bottom of the pipe is above the condensate drain pan
connection.
EHYKOMB33AA
Daikin Altherma hybrid heat pump – gas boiler module
4P353067-1L – 2022.09
14 Maintenance and service
8 Pull the bottom of the pipe forwards and remove the pipe
downwards by turning the pipe alternately clockwise and
counterclockwise.
Installation and operation manual