BM3 Installation & User Manual
1
SW1 push button. Used to set the password
and erase the memory.
2
Connection to the telephone system.
3
Exit button. Connect terminal nos 12 and 13.
Looped = door open. *)
4
Time control from the external time clock. In-
put 1: Connect terminal nos 11 and 13. Input
2: Connect terminal nos 10 and 13. Looped
input = the codes are disabled. *)
5
Camera relay output. *).
6
Tamper switch. Normally closed when the
housing is closed. *)
7
Power supply in, terminal nos 1 and 2.
8
Electric locking device. Dashed line refers to
locks with failsafe function. *)
9
Speaker volume.
10
Microphone sensitivity.
11
Jumper for 12 or 24 V voltage supply. If
above 20 V, set the jumper to 24 V.
*) Cable max 300 m.